ER-A310 (serv.man3). ERA310 330 Program Manual - Sharp ECR Service Manual (repair manual). Page 24

Read Sharp ER-A310 (serv.man3) Service Manual online

[JOB#2616]
OPTIONAL FEATURE
X: 1
MRS = 00000000
A:
OP X/Z report
A
Enable
0
Disable
1
B, C: Not used (Fixed at "00")
D:
"RFND" key entry in REG mode
D
Enable
0
Disable
1
E:
Direct void function in REG mode
E
Enable
0
Disable
1
F:
In direct void in REG mode
F
Enable
0
Disable
1
G:
Subtotal void in REG mode
G
Enable
0
Disable
1
H: Not used (Fixed at "0")
X: 2
MRS = 00000000
A:
The first last item void
A
Enable
0
Disable
1
 B, C: Not used (Fixed at "00")
D:
Printing of the number of purchases
D
No
0
Yes
1
E:
Time print
E
Yes
0
No
1
F:
Printing of journal
F
Full print
0
Journal select
1
G, H: Not used (Fixed at "00")
X: 3
MRS = 00000000
A:
Flash report in OP X/Z mode
A
Yes
0
No
1
 B:   Not used (Fixed at "00")
C:
Zero skip in Cashier report
C
Yes
0
No
1
D:
Zero skip in Transaction report
D
Yes
0
No
1
E:
Zero skip in Dept. report
E
Yes
0
No
1
F:
Zero skip in PLU report
F
Yes
0
No
1
G:
Zero skip in Hourly report
G
Yes
0
No
1
H:
Zero skip in Daily net report
H
Yes
0
No
1
X: 4  NOT USED
MRS = 00000000
A, B: Not used (Fixed at "00")
C:
Vat/Tax amount printing on R/J
C
Yes
0
No
1
D:
Taxable amount printing on R/J
D
Yes
0
No
1
E:
Net amount printing on R/J
E
Yes
0
No
1
F, G, H:  Not used (Fixed at "000")
[JOB#2617]
PROGRAMMING OF THE TIME INTERVAL FOR THE TILL TIMER
XXX: 0  
 255 sec
MRS = 000
2616
AB CDEFGH
X
No change
TL/NS
#/TM/ST
X
X
2617
XXX
0
TL/NS
X
– 23 –
Page of 29