Read Panasonic CS-E7MKDW / CU-E7MKD / CS-E9MKDW / CU-E9MKD / CS-E12MKDW / CU-E12MKD / CS-E15MKDW / CU-E15MKD / CS-E18MKDW / CU-E18MKD Service Manual online
2 Specifications ------------------------------------------------------5
3 Features ------------------------------------------------------------ 21
4 Location of Controls and Components------------------ 22
4.2. Outdoor Unit ----------------------------------------------- 22
4.3. Remote Control------------------------------------------- 22
5.2. Outdoor Unit ----------------------------------------------- 25
8.2. Outdoor Unit ----------------------------------------------- 32
9.2. Outdoor Unit ----------------------------------------------- 36
10.2. Outdoor Unit ----------------------------------------------- 41
11.2. Indoor Unit ------------------------------------------------- 44
11.3. Outdoor Unit ----------------------------------------------- 48
12.2. Indoor Fan Motor Operation--------------------------- 52
12.3. Outdoor Fan Motor Operation------------------------- 53
12.4. Airflow Direction ------------------------------------------ 53
12.5. Quiet operation (Cooling Mode/Cooling area
12.7. Powerful Mode Operation------------------------------ 55
12.8. Timer Control---------------------------------------------- 55
12.9. Auto Restart Control------------------------------------- 56
12.13. Mild Dry Cooling Operation---------------------------- 61
12.14. ECONAVI and AUTO COMFORT Operation------ 62
13.2. Soft Dry Operation --------------------------------------- 66
13.3. Heating Operation---------------------------------------- 66
13.4. Automatic Operation------------------------------------- 66
13.5. Indoor Fan Motor Operation--------------------------- 67
13.6. Powerful Mode Operation------------------------------ 67
13.7. Auto restart control--------------------------------------- 67
13.8. Indication Panel------------------------------------------- 67
13.9. Mild Dry Cooling Operation---------------------------- 67
14.2. Protection Control For Cooling & Soft Dry
15.2. Remote Control Button--------------------------------- 73
16.2. Breakdown Self Diagnosis Function ---------------- 76
16.3. Error Codes Table --------------------------------------- 77
16.4. Self-diagnosis Method---------------------------------- 79
17.3. Outdoor Electronic Controller Removal
18.2. Sensible Capacity Chart ------------------------------140
19.2. Outdoor Unit ---------------------------------------------147
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
the seriousness is classified by the following indications.
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the connection.
materials.
Thickness of copper pipes used with R410A must be more than 0.8mm. Never use copper pipes thinner than 0.8mm.
It is desirable that the amount of residual oil is less than 40 mg/10m.
etc.).
in explosion, injury etc.).
will tend to splash when heated too high (about 1100°F / 600°C).
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries,
permanent connection of this room air conditioner to the power supply is prohibited.
i. Power supply connection to the receptacle using a power plug. Use an approved 15/16A (3/4~1.75HP), 16A (2.0HP), 20A (2.5HP) or
Sharp parts may cause injury.