ER-A310 (serv.man3). ERA310 330 Program Manual - Sharp ECR Service Manual (repair manual)

er-a310 (serv.man3) service manual
Model
ER-A310 (serv.man3)
Pages
29
Size
986.73 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA310 330 Program Manual
File
er-a310-sm3.pdf
Date

Read Sharp ER-A310 (serv.man3) Service Manual online

PROGRAMMING MANUAL
CODE: 00ZERA310VPME
ELECTRONIC
CASH REGISTER
MODEL
 
ER-A310
MODEL 
ER-A330
(For "V" version)
SRV KEY :  LKGIM7113RCZZ
PRINTER : CR-510 (ER-A310)
:
 UCR-812A (ER-A330)
CHAPTER 1. SERVICE (SRV) MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
CHAPTER 2. PROGRAM (PGM) MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE . . . . . . . . . . . . . . . . . . . . . . . . . . .  27
CONTENTS
SHARP CORPORATION
ER-A310
ER-A330
CHAPTER 1. SERVICE (SRV) MODE
The SRV key is used for operating in the SRV mode.
1. SRV. reset (Program Loop Reset)
Used to return the machine back to its operational state after a lock-
up has occurred.
Procedure
Method 1
1) Turn off the AC switch.
2) Set the mode switch to (SRV
) position.
3) Turn on the AC switch.
4) Turn to (SRV) position from (SRV
) position.
Method 2
1) Set the mode switch to PGM2 position.
2) Turn off the AC switch.
3) While holding down JOURNAL FEED key and RECEIPT FEED
key, turn on the AC switch.
2. Master reset (All memory clear)
There are two possible methods to perform a master reset.
Used to clear all memory contents and return machine back to its
initial settings. return keyboard back to default. for default keyboard
layout.
Procedure-1 (with SRV key)
1) Unplug the AC cord from the wall outlet.
2) Set the MODE switch to the (SRV
) position.
3) Plug in the AC cord to the wall outlet.
4) While holding down JOURNAL FEED key, turn to (SRV) position
from (SRV
) position.
Procedure-2 (without SRV key)
1) Turn the mode switch to the (REG) position.
2) Ensure the batteries are not installed in the battery compartment
and insert the plug into the outlet.
3) The right most decimal point will blink for a few seconds.
4) The register will sound three beeps.
5) The register will display "
." 
3. Reading of the SRV mode program
List of program report
JOB#
REPORT NAME
900
SRV mode program full item report
(Not included the keyboard layout)
950
Keyboard layout report
[JOB# 900]
All parameters contained for the SRV mode as listed
Key operation
SRV mode
PGM mode
1
ER-A310
900
TL/NS
X
9900
X
TL/NS
– 1 –
2
ER-A330
[JOB# 950]
Keyboard layout programming report
Key operation
SRV mode
PGM mode
950
TL/NS
X
9950
X
TL/NS
– 2 –
1
ER-A310
– 3 –
Page of 29
Display

Download Sharp ER-A310 (serv.man3) Service Manual (Repair Manual)

Here you can read online and download Sharp ER-A310 (serv.man3) Service Manual in PDF. ER-A310 (serv.man3) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp ER-A310 (serv.man3) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.