  Adjustment Item
Adjustment Menu
Adjustment Point
Signal/Setting
Adjustment Contents
q
Sub colour
SCOLOR
Connect the synchroscope 100% colour bar Adjust the yellow amplitude of the colour bar
adjustment
to 4PIN (VB) of TP1900.
signal (white level to yellow peak level) to
2.5
±
0.1Vpp.
 
w
Confrontation
COM
Specified adjustment jig
No input state
When using the specified adjustment jig
bias adjustment
(illuminometer) or visual
Brightness: Center Connect the output of jig to the oscilloscope
observation
Perform it in a
and adjust the waveform to the minimum
combination of
point.
PWB and the
At this time, perform the adjustment several
liquid crystal
times to fix the optimal point because the
panel which will measuring value hardly changes around the
be supplied as
optimal point.
products finally.
In case of visual adjustment Stand or tilt the
panel as shown in the figure and check by
shaking your head and seeing whether stripes
appear.
If the adjustment is improper, you will see
stripes in the longitudinal direction.
Perform the adjustment so that they
do not appear.
[Another method] [Another method]
Flicker signal
Externally input the signal shown left and
generator
adjust so that the cross bars become minimum
“Example:
by visually checking the screen.
BP1018 made
by JFC”
e
OSD position
OSDH
OSD character
The position of the adjustment value on the
adjustment
visual observation
right end of the OSD character is adjusted to
15mm 
±
 2mm from the right end of the image
plane.
r
Lighting control
BBRIGHT
Check that the BBRIGHT is “76”.
standard check
(Type drawing)
Optimal point
Adjust within the above 
range to fix the optimal point
Direction of stripe
15mm
2.5V
±
0.1
White
Yellow
Page of 7