Read Sharp SM-SX1 (serv.man2) Service Manual online
SM-SX1H
– 2 –
Specifications for this model are subject to change without
prior notice.
prior notice.
SPECIFICATIONS
IMPORTANT SERVICE NOTES (FOR U.K. ONLY)
Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
set value
Withstanding Voltage Tester
Test voltage
2,120 VPEAK
1,500 VRMS
1,500 VRMS
Set time
60 secs
Set current(Cutoff current)
4 mA
Unit
Judgment
OK: The “GOOD” lamp lights.
NG: The “NG” lamp lights and the buzzer sounds.
NG: The “NG” lamp lights and the buzzer sounds.
SHORT-CIRCUIT
AC POWER
SUPPLY CORD
AC POWER
SUPPLY CORD
CONNECT THE PROBE
TO GND
TO GND
OF CHASSIS
SCREW
PROBE
AC
UNIT
WITHSTANDING
VOLTAGE TESTER
VOLTAGE TESTER
+
-
OUT
Rated output power:
RMS; 50 W + 50 W (DIN 45 500)
Total harmonic distortion:
0.02 % (1 kHz, 1 W)
Frequency response:
5 Hz - 20 kHz (+1 dB, -1 dB)
5 Hz - 100 kHz (+1 dB, -3 dB)
5 Hz - 100 kHz (+1 dB, -3 dB)
Dynamic range:
100 dB (10 Hz - 20 kHz)
A/D noise shaping:
7th-order
(delta-sigma) modulation
Input terminals:
DIGITAL1; RCA coaxial
DIGITAL2; Square type optical
SACD; RCA analog, 1 BIT digital
LINE 1,2; RCA analog (350 mV rms/50 k ohms)
DIGITAL2; Square type optical
SACD; RCA analog, 1 BIT digital
LINE 1,2; RCA analog (350 mV rms/50 k ohms)
Output terminals:
DIGITAL OUT; Square type optical
LINE OUT; RCA analog
Speakers; 8 ohms
LINE OUT; RCA analog
Speakers; 8 ohms
Power source:
Dimensions:
Width;
300 mm (11-13/16”)
Height;
2
66 mm (2-5/8”)
Depth;
411 mm (16-3/16”)
Weight:
Approx.
6.8 kg (15.0 lbs.)
Power source; 230V, 50Hz
Power consumption; 55W
Power consumption; 55W
Click on the first or last page to see other SM-SX1 (serv.man2) service manuals if exist.