SD-EX100H (serv.man18). Function table of IC - Sharp Audio Service Manual (repair manual). Page 9

Read Sharp SD-EX100H (serv.man18) Service Manual online

SD-EX100H
– 74 –
ICD02 RH-iX0566AW00: System Microcomputer (IX0566AW) [Serial N0. 20500065 to 20501035] (1/3)
ICD02 RH-iX0566AWZZ: System Microcomputer (IX0566AW) [From Serial N0. 20601036] (1/3)
In this unit, the terminal with asterisk mark (*) is open terminal which is not connected to the outside.
1
P96/ANEX1/SOUT4
FLD_SDATA
Output
Display data output to FL driver M66005
2
P95/ANEX0/CLK4 FLD_SCK
Output
Serial clock output to FL driver M66005
3
P94/DA1/TB4IN
TRY_M+ (D/A)
Output
CD Tray OPEN/CLOSE control motor normal rotation control output
D/A output  (Three-valued output)
4
P93/DA0/TB3IN
TRY_M– (D/A)
Output
CD Tray OPEN/CLOSE control motor inversion control output
D/A output  (Three-valued output)
5
P92/TB2IN/SOUT3 FLD_CS
Output
Chip select output to FL driver M66005
6*
P91/TB1IN/SIN3
Output
Port processing.  Fixed at "L".
7*
P90/TB0IN/CLK3
Output
Port processing.  Fixed at "L".
8
BYTE
BYTE
Input
External bus unused; connected to VSS
9
CNVSS
FLASH_VCC
Input
Used in single chip mode.
Connected to VSS via pull-down resistor
In case of Flash writing: VCC exclusively for exterior
10
P87/XCIN
XCIN
Input
Crystal for clock 32,768 kHz connected
11
P86/XCOUT
XCOUT
Output
Crystal for clock 32,768 kHz connected
12
RESET
RESET
Input
Reset input for the microcomputer.  Active: "L".
In case of Flash writing: Connect to RESET
13
XOUT
X_OUT
Output
Reference oscillation output for the microcomputer
8.4 MHz CERALOCK connected
14
VSS
VSS
Connected to GND (VSS)
15
XIN
X_IN
Input
Reference oscillation output for the microcomputer
8.4 MHz CERALOCK connection
16
VCC
VCC
Input
Power supply to the microcomputer (3.3V)
Backup power supply
17
P85/NMI
NMI
Input
Connected to VCC via pull-up resistor
(Setting in case of FLASH writing)   Functionally unused.
18
P84/INT2
P_IN
Input
Power failure detection input
Power failure detected according to detection time "H" 
  "L".
19*
P83/INT1
Output
Port processing.  Fixed at "L".
20
P82/INT0
RX_IN
Input
Remote control input by SHARP system
21*
P81/TA4IN/U
Output
Port processing.  Fixed at "L".
22*
P80/TA4OUT/U
Output
Port processing.  Fixed at "L".
23*
P77/TA3IN
Output
Port processing.  Fixed at "L".
24*
P76/TA3OUT
Output
Port processing.  Fixed at "L".
25*
P75/TA2IN/W
Output
Port processing.  Fixed at "L".
26
P74/TA2OUT/W
P_DOWN
Output
"H" for power ON.  "L" for power failure.
27*
P73/CTS2/RTS2/TA1IN/V —
Output
Port processing.  Fixed at "L".
28*
P72/CLK2/TA1OUT/V —
Output
Port processing.  Fixed at "L".
29*
P71/RXD2/SCL/TA0IN/TB5IN —
Output
Port processing.  Fixed at "L".
30*
P70/TXD2/SDA/TA0OUT —
Output
Port processing.  Fixed at "L".
31
P67/TXD1
(MD)K_DATA
Output
K Data output serial 32 bytes.  Automatic reception/transmission
FLASHTXD
(Transmission data output to FLASH writer)
32
P66/RXD1
(MD)MD_DATA
Input
MD Data input serial 32 bytes. Automatic reception/transmission
FLASHRXD
(Transmission data output to FLASH writer)
33
P65/CLK1
(MD)DSCK/
Output
MD Clock output serial 32 bytes. Automatic reception/transmission
FLASHSCLK
 (Transmission data output to FLASH writer)
34
P64/CTS1/RTS1/CTS0/CLKS1 (MD)D_STB/
Input
MD_STB Input.  For transmission control
FLASHBUSY
 (Transmission data output to FLASH writer)
35
P63/TXD0
Output
Port processing.  Fixed at "L".
36
P62/RXD0
Output
Port processing.  Fixed at "L".
Pin No.
Function
Port Name
Terminal Name Input/Output
Page of 14
Display

Click on the first or last page to see other SD-EX100H (serv.man18) service manuals if exist.