CD-MD3000H/CD-MD3000W
– 32 –
Test mode name
I
N
I
T
I
A
L
Set-Up Complete
Function
F
I
N
I
S
H
Character display
Item
Type
Auxiliary display
1
2
3
4
5
6
7
8
9 10
Auxiliary display
Note
Outline
While the unit is turned off, press the POWER key while holding down the VOLUME-DOWN and PANEL OP/CL keys to enter
the test mode selection mode. Then, the unit is started, the panel is opened, and the microcomputer's version/destination/span
is displayed. If the following data is entered from the keyboard while in the test mode selection mode, the unit directly enters
the specified test mode. This operation is applied to the main unit's keys only.
In the destination display, a destination code (H/W/U/J) is displayed. For the span display, "9" means 9 kHz/50 kHz, and "10"
means 10/100 kHz. All pictures will disappear except the characters.
By pressing the specific key, you can enter the test mode whose functions are as follows:
Menu display
Shortcut Key
Model
System
INITIAL
CD1 PLAY
ALL
Shipping status setting
SOFT_RESET
CD2 PLAY
ALL
Soft rest
CD
CD_TEST
CD1 EJECT
ALL
CD test
Tuner
TUN_PRESET
CD4 EJECT
ALL
Tuner test frequency preset
TUNER_TEST
CD5 EJECT
ALL
Tuner test
MD
MD_TEST
CD
ALL
MD test
Outline of Test Mode
Shipping status setting test mode
Purpose:   To set up the unit for shipping.
Function:   Initialize all functions.
Operation:  All settings are initialized, "FINISH" is displayed as in the sample display, and data entry is prohibited including data
to turn on or off the unit.
TEST MODE
Version • Destination
V
*
*
    Left adjust in the first line
Character display
Example: V1. 1_W:_9
Destination
Number
Span
Item
Type Auxiliary display
1
2
3
4
5
6
7
8
9 10
 Auxiliary display
Note
To exit the test mode
The unit returns to the normal operation through reset entry.
Table Character display for test mode 1
In the destination display, a destination code is displayed. For the span display, "9" means 9 kHz/50 kHz, and "10" means 10/
100 kHz.
Name
Description
1
Shipping status setting
Sets up the unit for shipping.
2
Soft set setting
Initializes the unit.
3
CD test
Performs tests such as the CD mechanism test, hardware test, and constant setting test.
4
Tuner test
Presets the test frequency.
frequency preset
5
Tuner preset clear setting
Clears all presets.
6
MD test
Setting MD micro computer to test mode.
– 33 –
CD-MD3000H/CD-MD3000W
2. Soft reset
Purpose:     To initialize the unit.
Function:     To initialize all functions.
Operation:   "ALL CLEAR" is displayed, all functions are initialized, and the unit is turned on.
To exit the test mode
When the initialization through soft reset is complete, the unit is turned on.
Table Character display for test mode 2
3. CD test mode (If this test mode is not activated, refer to CD troubleshooting on page 89.)
In the CD test mode, each step can be performed even if the LID-SW is off. However, if you cannot obtain a focus in step
3 or if other kind of error handling starts, you cannot proceed to the following steps. In error handling, press the POWER key
to exit the test mode, or press the STOP key to prohibit operations other than returning to step 1.
(1) Step 1 mode
In the CD test mode, the following display appears, CD initialization is performed, and you are prompted for data.
Reset operation display / Operation
"CD_TEST"
After lighting up for one second
"T1___________0:00"
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FWD" ................ While holding down this key, the pickup moves outward after returning to the innermost track.
"REV" ................. While holding down this key, the pickup moves inward after returning to the innermost track.
"PLAY" ............... Jumps to step 2.
"STOP" ............... Cancelled.
"TAPE REC" ...... Jumps to step 5.
*  While the pickup is moving to the innermost track in the initialization, none of the keys except POWER is accepted. When PU-
IN SW ON cannot be detected in ten seconds, the unit stops the slide motor and shows the following error code. Then, you
can press the POWER key to exit the test mode, or the STOP key to return to step 1. You cannot perform other operations.
"E--CD01"
(2) Step 2 mode
   When the "PLAY" key is pressed in the above mode, the laser is turned on. At this time, another operation must not be
performed.
Display          "T2___________0:00"
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FWD" ................. While holding down this key, the pickup is moved outward.
"REV" .................. While holding down this key, the pickup is moved inward.
"PLAY" ................ Jumps to step 2.
"STOP" ............... Returns to step 1.
"TAPE REC" ....... Jumps to step 5.
Reset operation
Operation
A
L
L
C
L
E
A
R
display
Character display
Item
Type
Auxiliary display
1
2
3
4
5
6
7
8
9 10
Auxiliary display
Note
(3) Step 3 mode
   Performs focus search and turns on the focus servo.
   Focus search is repeated until it is brought into focus.
Display          "T3___________0:00"
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FF/FWD" ........... While holding down this key, the pickup is moved outward.
"REW/REV" ........ While holding down this key, the pickup is moved inward.
"PLAY" ................ Jumping to step 4 when a focus is obtained. Otherwise, data entry is prohibited.
"STOP" ............... Returns to step 1.
"TAPE REC" ....... Jumps to step 5.
* You should return to step 1 if it is out of focus after bringing it into focus.
CD-MD3000H/CD-MD3000W
– 34 –
(4) Step 4 mode
   Rotate a disc.
Displayed string:         "T4___________0:00"
The clock display should always be "0:00".
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FF/FWD" ........... While holding down this key, the pickup is moved outward.
"REW/REV" ........ While holding down this key, the pickup is moved inward.
"PLAY" ................ Jumps to step 5.
"STOP" ............... Returns to step 1.
"TAPE REC" ....... Jumps to step 5.
* You should return to step 1 if it is out of focus.
(5) Step 5 mode
 Start playback. When the pickup reaches the outermost track, it does not stop. The LCD screen shows the replay time  elapsed
as in the normal CD playback.
Display         "T5___________0:00"
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FWD" ................. While holding down this key, the pickup is moved outward.
"REV" .................. While holding down this key, the pickup is moved inward.
"PLAY" ................ Canceled.
"STOP" ............... Returns to step 1.
* You should return to step 1 if it is out of focus.
Notes:
• In the test mode, TOC IL is not performed.
• Only the keys for adjusting the volume are accepted except the keys described.
4. Tuner test frequency preset
Purpose:
To preset a test frequency for an in-factory test.
Function:
To preset each preset number to the band and frequency shown in Table 34 based on the initial setting for the
destination.
Operation:
To preset the band and frequency shown in the table below and turn the unit on with the following setting.
Function
Tuner
Band
FM monaural
Tuning mode
Preset call selection
Call preset number
Preset number 1 frequency
Band's last preset channel
See Table 34
X-BASS
Off
Preset equalizer
FLAT
For other functions, the value which was set when the unit was turned off last time is valid (last state).
To exit the test mode
After the frequency is preset and the set-up is done, the unit is turned on and normal operations start.
1 %
FM   87.5 MHz
FM   87.5 MHz
2
FM 108.0 MHz
FM 108.0 MHz
3
FM
FM   90.0 MHz
FM   90.0 MHz
4
FM 106.0 MHz
FM 106.0 MHz
5
FM   98.0 MHz
FM   98.0 MHz
6 %
AM   522 kHz
AM   531 kHz
7
AM 1620 kHz
AM 1602 kHz
8
AM
AM   603 kHz
AM   603 kHz
9
AM 1404 kHz
AM 1404 kHz
10
AM   990 kHz
AM   990 kHz
11-40
Table 34. TEST-TuSet preset frequencies
Unused channels are indicated with "––".
"%" indicates the last channel for each band.
All FM bands are preset to FM monaural.
BAND
CD-MD3000H
CH
CD-MD3000W
– 35 –
CD-MD3000H/CD-MD3000W
MD SECTION
Enter the test mode, adjust or set as shown in the following table according to the repair operations.
PICK replacement 
HEAD replacement 
MECHANISM 
replacement
MAIN PWB
assembly replacement
MD microcomputer
replacement
MD LSI replacement
RF IC replacement
EEPROM IC
replacement 
TEMP
basic
setting
TEMP
Execution item
required
Repair
operations
number        to      and
" – " is an item that you don't have to execute.
The EEPROM writing result is shown at the end of the test mode
Although "SET" was written normally, it was not written in the "YOBI COMPLETE" state.
Peform "AUTO-YOBI" adjustment. After making a normal adjustment, 
write the preliminary adjustment into the EEPROM.
OK_EEPROM: "SET" and "YOBI COMPLETE" were written normally
WR_EEPROM:
NG_EEPROM: "SET" could not be written.
indicate the order of inplementation.
Checking
EEPROM
setting
EEPROM_SET
AUTO-YOBI
adjustment
AUTO-
adjustment
AUTO-FAB
adjustment
AUTO–YOBI AUTO–ADJ AUTO–FAB TEST-CANCEL
Writing the
EEPROM
setting
TEST-CANCEL
Writing the
EEPROM
setting
TEST-PLAY
Operation check
TEST-REC
Check the connection between the MD microcomputer and the EEPROM.
1
1
1
1
1
1
1
2
2
2
1
2
2
3
3
3
2
3
3
4
4
4
3
4
4
5
5
5
4
2
5
5
6
6
6
5
3
6
6
7
7
7
8
9
6
5
8
1
8
9
9
9
4
7
7
8
8
8
5Pin extension flat cable
QCNWK0109AFZZ
2Pin extension connector
QCNWK0129AFZZ
MD MAIN PWB
6Pin extension flat cable
QCNWK0130AFZZ
28Pin extension flat cable
QCNWK0108AFZZ
Extension PWB for service
(RUNTK0532AFZZ)
Fit the extension PWB for service to the mechanism
From Optical
Pickup Unit
From Magnetic Head
From mechanism
switch PWB
Extension Cable
Type
1
Extension PWB for servicing
RUNTK0532AFZZ
2
Extension Connector (2 Pin)
QCNWK0129AFZZ
3
Extension Cable (6 Pin)
QCNWK0130AFZZ
4
Extension Cable (5 Pin)
QCNWK0109AFZZ
5
Extension Cable (28 Pin)
QCNWK0108AFZZ
Part No.
Figure 35
Page of 11
Display

Download Sharp CD-MD3000 (serv.man8) Service Manual (Repair Manual)

Here you can read online and download Sharp CD-MD3000 (serv.man8) Service Manual in PDF. CD-MD3000 (serv.man8) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp CD-MD3000 (serv.man8) System. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.