CD-MD3000 (serv.man8). Test mode details - Sharp Audio Service Manual (repair manual). Page 3

Read Sharp CD-MD3000 (serv.man8) Service Manual online

CD-MD3000H/CD-MD3000W
– 34 –
(4) Step 4 mode
   Rotate a disc.
Displayed string:         "T4___________0:00"
The clock display should always be "0:00".
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FF/FWD" ........... While holding down this key, the pickup is moved outward.
"REW/REV" ........ While holding down this key, the pickup is moved inward.
"PLAY" ................ Jumps to step 5.
"STOP" ............... Returns to step 1.
"TAPE REC" ....... Jumps to step 5.
* You should return to step 1 if it is out of focus.
(5) Step 5 mode
 Start playback. When the pickup reaches the outermost track, it does not stop. The LCD screen shows the replay time  elapsed
as in the normal CD playback.
Display         "T5___________0:00"
The keys you can press here and the resulting operations are as follows:
"POWER" ........... The test mode is turned off, the power is turned off, and the unit is placed in the normal stand-by mode.
"FWD" ................. While holding down this key, the pickup is moved outward.
"REV" .................. While holding down this key, the pickup is moved inward.
"PLAY" ................ Canceled.
"STOP" ............... Returns to step 1.
* You should return to step 1 if it is out of focus.
Notes:
• In the test mode, TOC IL is not performed.
• Only the keys for adjusting the volume are accepted except the keys described.
4. Tuner test frequency preset
Purpose:
To preset a test frequency for an in-factory test.
Function:
To preset each preset number to the band and frequency shown in Table 34 based on the initial setting for the
destination.
Operation:
To preset the band and frequency shown in the table below and turn the unit on with the following setting.
Function
Tuner
Band
FM monaural
Tuning mode
Preset call selection
Call preset number
Preset number 1 frequency
Band's last preset channel
See Table 34
X-BASS
Off
Preset equalizer
FLAT
For other functions, the value which was set when the unit was turned off last time is valid (last state).
To exit the test mode
After the frequency is preset and the set-up is done, the unit is turned on and normal operations start.
1 %
FM   87.5 MHz
FM   87.5 MHz
2
FM 108.0 MHz
FM 108.0 MHz
3
FM
FM   90.0 MHz
FM   90.0 MHz
4
FM 106.0 MHz
FM 106.0 MHz
5
FM   98.0 MHz
FM   98.0 MHz
6 %
AM   522 kHz
AM   531 kHz
7
AM 1620 kHz
AM 1602 kHz
8
AM
AM   603 kHz
AM   603 kHz
9
AM 1404 kHz
AM 1404 kHz
10
AM   990 kHz
AM   990 kHz
11-40
Table 34. TEST-TuSet preset frequencies
Unused channels are indicated with "––".
"%" indicates the last channel for each band.
All FM bands are preset to FM monaural.
BAND
CD-MD3000H
CH
CD-MD3000W
Page of 11
Display

Click on the first or last page to see other CD-MD3000 (serv.man8) service manuals if exist.