AU-X095 - Sharp Air Conditioner Service Manual (repair manual). Page 8

Read Sharp AU-X095 Service Manual online

8
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Specification Switching Circuit No. 1
HIGH or LOW is input to the CPU depending on whether or not each jumper line is connected. When the jumper line is
connected, the 5V becomes directly connected and the input becomes HIGH. If the jumper line is disconnected, the
input is pulled LOW by the internal pull-down resistor in the CPU port. The CPU receives this HIGH/LOW input and
switches its programming specifications accordingly.
Light Reception Circuit
The remote control sends a waveform composed of a carrier waveform and a signal waveform as an infrared signal.
The light receiver unit removes the carrier waveform leaving only the signal waveform and inputs it to the CPU.
LED Circuit
LED 101 and LED 102 are lit by sending a LOW output from CPU IC1 pins 42 and 43. These LED's are lit when the unit
is in operation or when the timer is set.
+
5V
Light receiver unit
C9
C102
C101
CPU (IC1) pin 40
CPU (IC1) pin 41
R9
R10
5V
LED101
LED102
R11
CPU (IC1) pin 43
CPU (IC1) pin 42
5V
Jumper
CPU (IC1) 
Outdoor unit minimum frequency
       ––––
Model switch
Outdoor unit maximum frequency
       ––––
Model switch
       ––––
Wireless switch
Pre-heat function
 
Jumper
Yes
No
Up
                                 ––––
Cooler only
Down
                                 ––––
X075
                                 ––––
Switch
No pre-heat
Normal
Cooler/heater
Normal
  
X095
Normal
Pre-heat
Page of 32
Display