Indoor Unit Control Circuit Operation
The indoor unit control circuit is constructed around a CPU. Its main functions are reception of signals from the remote
control, transmission and reception of signals from the outdoor unit, control of the indoor fan motor, and control of the
louver motor.
Power On Circuit
If a jumper has been inserted at the position indicated by the dotted line in the diagram above, when the indoor power
socket is plugged in, CPU IC1 pin 39 goes HIGH (5V) and automatic mode operation begins.
Power Supply Circuit
The 220/240 V AC shown in the diagram above is generated when the indoor power socket is plugged in. The voltage
is lowered by the transformer TR. The voltage on the secondary side of the transformer is approximately 16 V AC. The
diode bridge formed by D1 to D4 performs full-wave rectification on this voltage. The resulting waveform is then
smoothed by capacitor C3, and finally approximately 17 V DC is asserted at both ends of C4. When this 17 V DC is
input to IN and GND of the 3-terminal regulator IC3, a stable voltage of 12 V DC is output across OUT and GND. The
17 V DC also passes through R3 to the Zener diode ZD1 and a stable voltage of 5 V can be obtained at both ends of
ZD1.
CPU (IC1) pin 39
5V
+
C4
ZD1
C3
D2
D1
AC 220/240V
12V
5V
R3
IN
OUT
GND
D4
D3
C6
+
IC3
C5
+
TR