AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Reset Circuit
The 5V power for the indoor control circuit is generated when the indoor power socket is plugged in. At the same instant
as the 5V power is generated, C13 becomes conductive, the base of transistor Q3 goes HIGH (5V), and Q3 goes ON.
When Q3 goes ON, CPU IC1 pin 12 goes LOW resetting the CPU. Afterwards, C13 becomes charged and non-
conductive, Q3 goes OFF, and CPU IC1 pin 12 becomes HIGH input. When this happens, the CPU operation starts and
control is performed.
+
C14
D8
Q3
R17
C13
5V
CPU (IC1) pin 12
5V
0V
5V
0.5 sec.
0V
CPU pin 12
input voltage
5V Power supply waveform
Power plug
inserted
Page of 32
Display