60
AY-XM7/9/12CR
AY-XPM7/9/12CR
AE-XM18/24CR
CN1
CN5
CN4
CN3
9. Remove 2 screws fixing the sensor holder, lead cover
A and lead cover B from the evaporator.
NOTE : In case of AY-XPM7CR, AY-XPM9CR
10-1.Cut off 2 fixing bands.
During reassembly, fix them by fixing bands as same
certainly.
NOTE : In case of AY-XPM12CR
10-2.Cut off 3 fixing bands.
During reassembly, fix them by fixing bands as same
certainly.
11. Remove 2 thermistors of the evaporator and the pipe.
12.Remove 4 conectors.
13. Pushing the 2 hooks of the holder, remove the display
board unit 3 from the holder.
And remove 2 screws fixing the cluster holder from the
drain pan.
14.Remove 3 screws fixing the LED HOLDER B
15. Remove the screw fixing the pipe holder.