AE-X08 (serv.man19). Air conditioner stops and shows error code 14 on display unit. - Sharp Air Conditioner Technical Bulletin (repair manual). Page 2

Read Sharp AE-X08 (serv.man19) Technical Bulletin online

AIR2002 10 01
Month of Issue:  
October 2002
        
Classification: 
White
AIR CONDITIONER TECHNICAL BULLETIN
Page 2 of 2
Sharp Electronics (UK) Limited
Reference EHH-157
Revision 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red
Carry out on all units
3. Remove two screws holding the PWB
and unlock two spacers.
4.
Remove the screw holding the
capacitor band and remove the band.
5. Disconnect the lead wires.
6. Connect lead wires to 1500μF
capacitor as original and install with
new capacitor clamp using another
screw hole.
* The blue lead wire should be
connected to the white line side
terminal.
(Refer to the above picture.)
7. Re-assemble the unit.
Use this hole for new band fixing with the screw.
A screw
White line on the capacitor
Blue lead wire
Red lead wire
Two screws
Two spacers
Page of 2