TC-51P100G, TC-51P100H - Panasonic TV Service Manual (repair manual). Page 15

Read Panasonic TC-51P100G / TC-51P100H Service Manual online

- 15 -
Preparation:
1. Set  X-ray protector adjustment VR, R581 (on E-
Board) fully counterclockwise.
2. Set  EHT adjustment VR, R598 (on E-Board) fully
counterclockwise.
3. Connect the positive lead (+) of a DVM to TPE1
and the negative lead (-) to TPE2 (on E-Board).
4. Connect a high voltage meter between  anode and
ground.
5. Set the TV to MARKET MODE (CHK3) 
EHT PROTECT............ON
Procedure:
1. Receive a monoscope pattern.
2. Adjust  EHT adjustment VR, R598, until the high
voltage meter measures 34.5kV ± 0.5kV.
3. Adjust Sub Contrast or Sub Bright or Screen VR
until the DVM (ABL current) measures 1400 ±
30
P
A.
4. Repeat step 2. ~ step 3. until the voltages mea-
sured are as specified.
5. Slowly turn the X-ray protector adjustment VR,
R581 clockwise until the On Screen Display (OSD)
is just RED.
6. Turn the EHT adjustment VR, R598 fully counter-
clockwise.
7. Slowly turn the EHT adjustment VR, R598, clock-
wise and confirm that the X-ray protector operates
when the high voltage reaches 34.5kV ± 0.5kV.
8. Confirm that DVM (ABL current) measures 1400 ±
30
P
A when the X-ray protector operates.
9. If the measurements in step 7. ~ step 8. do not
confirm, repeat step 2. ~ step 9.
10. Turn power off.
11. Fill sleeves with silicone and carefully place over
VR R598 & VR R581.  (See Figure A.)  Avoid acci-
dental changing the setting while placing the
sleeve over VRs.
Figure A. Sealing of HV resistor
Note: Allow approximately 5 minutes for silicone to
harden before turning the PTV on.
Sillicone
Sleeve
Variable
Resistor
PC Board
X-ray Protection and High Voltage Adjustment