AW-E600E - Panasonic Provideo Service Manual (repair manual). Page 6

Read Panasonic AW-E600E Service Manual online

3
1. Test Equipment Required
8
The following test Equipments are required for
adjustment of the Convertible Camera AW-E600E.
8
Oscilloscope
8
Frequency Counter
8
Digital Voltmeter
8
Vectorscope
8
Waveform Monitor
8
Underscanned Colour Video Monitor
8
Signal Generator
8
12 V DC Power Supply Unit
8
Lux Meter
8
Lighting (200 footcandles (2,000 lx), Colour Temperature
3,200 K)
8
Auto Iris Lens (1/2" Bayonet-Mount)
8
Camera Cables AW-CA50T6
8
Remote Control Box (WV-CB700A)
8
1/2 ND Filter (2 pieces)
8
RCB Cable (AW-CA50T10)
8
Logarithmic Gray Scale Chart (Part No. : YWV2310RB99)
8
Extension Board between Joint Board and Preprocess or
DSP/Encoder Board (Part No. : 0E1A020A)
8
Extension Board between Power Board and Option Card
(Part No. : 0E1A021A)
8
Extension Board between Joint Board and Preamp. Board
(Part No. : 0E1A036A)
8
Extension Board between Joint Board and Drive Board
(Part No. : 0E1A037A)
ADJUSTMENT PROCEDURE
8
Extension Board between CCD and Preamp. Board (Part
No. : 0E1A038A)
8
Extension Board between CCD and Drive Board (Part No.
: 0E1A039A)
8
Extension Board between Joint Board and Preamp.
Board (Part No. : 0E1A040A)
8
Manual Adjustment Card (Part No. : 0E1A022A)
2. Disassembling Procedure for
Adjustment
8
Referring to Fig. 2-1, remove four screws that secure the
Rear Panel and remove the Rear Panel.
Fig. 2-1
Remove four screws.
Rear Panel
R
G
B
SIGNAL GND
VIDEO OUT
VIDEO GND
GND
28MHz
28MHZ GND
VD
HD
15.5V
12V (UNREG)
R  PEDE
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
WRITE SW
WIDE TELE
NEAR FAR
ZOOM SW GAIN SW
IRIS  VR
LENS CN
IRIS CONT SW
FOCUS SW
R  GAIN
R  PULCAN
G  PEDE
G  GAIN
G  PULCAN
B  PEDE
B  GAIN
B  PULCAN
7V
3V
2.5V
0.5V
–5V
–9V
GND
CAMERA  SIDE