AW-E600E - Panasonic Provideo Service Manual (repair manual). Page 11

Read Panasonic AW-E600E Service Manual online

– 8 –
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS
R283 (INT 8FSC)
PREAMP.-BOARD (PATTERN  SIDE)
PREAMP.-SUB
BOARD
(PATTERN  SIDE)
DSP / ENCODER  BOARD (PATTERN  SIDE)
PREPROCESS  BOARD (PATTERN  SIDE)
TP2 (INT 8FSC)
R555
(R-GAN)
R707
(B-WCLP)
R705
(R-WCLP)
R701
(G-WCLP)
R527
(R-DC1)
R355
(G-GAN)
R327
(G-DC1)
R363 (G-DC2)
R563 (R-DC2)
E7
(GND)
E103
(B)
E101
(B-IN)
E303
E203
E103
E304
E204
E104
E305
(B-OUT)
E205
(G-OUT)
E105
(R-OUT)
E201
(G-IN)
E101
(R-IN)
E301
(B-IN)
E302
E202
E102
E301
(G-IN)
E501
(R-IN)
E102
(B-OUT)
E1 (GND)
E302
(G-OUT)
E502
(R-OUT)
E303
(G)
E503
(R)
R127
(B-DC1)
R155
(B-GAIN)
R163
(B-DC2)
(2).2. Gain Adjustment
Test Point:
VIDEO OUT
Manual Adjustment Card
Adjust:
R GAIN VR
Manual Adjustment Card
G GAIN VR
Manual Adjustment Card
B GAIN VR
Manual Adjustment Card
8
Set the Lens Iris to F11.
8
Press the R GAIN SW ( which has been illuminated) on
the Manual Adjustment Card, and adjust Video Signal
Level by the R GAIN VR.
8
Press the G GAIN SW ( which has been illuminated) on
the Manual Adjustment Card, and adjust Video Signal
Level by the G GAIN VR.
8
Press the B GAIN SW ( which has been illuminated) on
the Manual Adjustment Card, and adjust Video Signal
Level by the B GAIN VR.
8
Repeat adjust R GAIN, G GAIN and B GAIN so that all
levels become satisfactory.
(2).3. Pulse Cancel Adjustment
Test Point:
VIDEO OUT
Manual Adjustment Card
Adjust:
R PULCAN VR
Manual Adjustment Card
G PULCAN VR
Manual Adjustment Card
B PULCAN VR
Manual Adjustment Card
8
Close the Lens Iris.
8
Set the GAIN SW on the Manual Adjustment Card to 30
dB.
8
Press the R PULCAN SW (which has been illuminated) on
the Manual Adjustment Card, and adjust Pulse Cancel
Level by the R PULCAN VR.
8
Press the G PULCAN SW (which has been illuminated) on
the Manual Adjustment Card, and adjust Pulse Cancel
Level by the G PULCAN VR.
8
Press the B PULCAN SW (which has been illuminated) on
the Manual Adjustment Card, and adjust Pulse Cancel
Level by the B PULCAN VR.
8
Repeat adjust R Pulse PULCAN, G PULCAN and B
PULCAN so that all levels become satisfactory.
8
Repeat adjust from Item (2).1. to Item (2).3. so that the
Pedestal Level Adjustment, Gain Adjustment and Pulse
Cancel Adjustment have been  satisfied.
8
After completion of adjustment, to select the adjusted Item
(which has been illuminated) and press the WRITE SW on
the Manual Adjustment Card slowly and release it.
HD and VD Signals, Voltage, Video Signal and
Clock Pulse Confirmation
8
Can be confirmed Internal HD and VD Signals, DC Power
Sources, Video Signals (R,G,B and Composite signal
outputs at the Preprocess Board) and Clock Pulse (28
MHz) at each Test Point at the Manual Adjustment Card.
Motor Drive Lens Control
8
Turn OFF the power of the AW-E600E.
8
Connect the Iris Cable to the Iris Connector on the Rear
Panel of the AW-E600E, and connect the I/F Remote
Connector to the LENS CN on the Manual Adjustment
Card.
8
Set the AUTO/MANUAL Switch to AUTO position.
8
Turn ON the power of the AW-E600E.
8
Set the IRIS CONT SW on the Manual Adjustment Card to
the LOCAL so that the Iris has been controlled by the IRIS
VR on the Manual Adjustment Card (close at fully
counterclockwise direction and open at fully clockwise
direction).
8
Set the IRIS CONT SW on the Manual Adjustment Card to
the CAMERA so that the Lens has been operated as the
ALC Mode.
8
Either press the ZOOM SW (WIDE/TELE) and FOCUS
SW (NEAR/FAR), activates the Zoom and/or Focus.
Page of 44
Display