SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
  5. 2. Service
    5. 2. 1. Supporting Methods
The basic service policy is shown below.
PC-P.C.Board (Specified components are replaced)
D-P.C.Board
DMD block (Specified components are replaced)
Lens unit
LD unit
Rod ASSY
    5. 2. 2. Jig and Tool
1. Hexalobe (TORX type) driver [2.72 mm]
VESSEL T10H or comparable product
Part No. : TZSH07035
2. Hexalobe (TORX type) driver [3.94 mm]
VESSEL T20H or comparable product
Part No. : TZSH07042
3. Hex wrench  [2.5 mm]
Use the Hex wrench on the commercially available.
4. Laser safety glass
Please wear glasses for safety when checking with the cover removed.
Type : Full absorption, Adaptation laser : Ar, Wavelength : 448 - 462nm
Part No. : TZSH07038  (or comparable product)
    5. 2. 3. Repair
1. Energization check and adjustment, after assembling the lighting block completely.
Before turning on the power, please make sure that the lighting block is completely assembled.
The service engineer who works on this model and also other people who are in the same room need
to wear the laser safety glasses for avoiding the laser irradiation just in case.
2. Before repair, make sure to turn off the main power and unplug the power cord from the power outlet.
* When replacing the print board, the internal electrical parts can be broken by the static electricity of clothes or
  human body. Be careful of static electricity and wear the anti-static electricity gloves.
3. After repairing, please check the gradation (10step or the gray scale) test pattern or moving image. 
    Also, please check that it is ormal on a self check screen.
4. Do handling and safekeeping carefully because the user setup information remains in the projector.
    5. 2. 4. Replacement of A-P.C. board
1. When the replacement of A-P.C.Board (assembly) is needed, back up the memory information such as adjustment data
    from the old board to PC with the service soft. Then transfer this data to the new A-P.C.Board.
    For more information refer to the SECTION 3 "Adjustment".
2. If you cannot transfer the data that uses the service software, remove [ IC3711 ] from the original board and mount
    them on the new board.
3. When A-P.C.Board is replaced, the MAC address of wired LAN will be changed. Explain it to the customers in advance.
Applied parts
        Other electrical parts and mechanism parts
Repair contents
  Block replacement
  P.C.Board replacement
  Replaced by discrete components
INF - 21