SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
4. Operation
Specifies the method of processing the value specified by parameters.
 
Description
 
Sets the value specified by the parameter.
 
Adds the value specified by the parameter to the current value.
5. Sign
Specifies positive or negative of the value specified by parameters.
 
Description
 
The value specified by the parameter is a positive value or 0 (zero).
 
The value specified by the parameter is a negative value.
6. Parameters
Specify the setting or adjustment value by right justification (0 is not suppressed).
For example, when the setting value is "1", set it as "00001".
7. ID of the basic control command
This projector will respond to the computer only in the following cases.
    - If the sent ID coincides with the projector ID.
    - RESPONSE(ID ALL) in RS232C settings of this projector is ON and the sent ID is ALL.
    - Or If Group (A-Z) of the sent ID coincides with GROUP in RS232C settings of this projector and
       RESPONSE(ID GROUP) in RS232C settings of this projector is ON.
Specifically, please refer to a separate volume "Control Commands". 
8. Response (Callback) of the basic control command
In the period when the command can be accepted.
Differs according to each command.
In the period when commands cannot be accepted.
In case of the parameter error or REMOTE2 effective.
9. Attention
If a command is transmitted after the light source starts illuminating, there may be a delay in response or 
the command may not be executed. Try sending or receiving any command after 60 seconds.
When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response 
from the projector before sending the next command. 
When transmitting a command which does not need a parameter, a colon (:) is not necessary.
It might take time by the time the response returns because the command is processed in the projector.
Set the time-out to 10 seconds or longer.
When multiple projectors are all controlled
1) Set a different ID for each projector.
2) Set [RESPONSE(ID ALL)] to [ON] in only one projector.
3) Set [RESPONSE(ID ALL)] to [OFF] for all other projectors set in Step 2).
When multiple projectors are all controlled by group unit
1) Set a different ID for each projector.
2) Set [RESPONSE(ID GROUP)] to [ON] in only one projector.
3) Set [RESPONSE(ID GROUP)] to [OFF] for all other projectors set in Step 2).
Code
=
52h
Code
_( underbar)
34h
Hexadecimal
30h
31h
02h
45h
Hexadecimal
03h
E
R
4
0
2
03h
Character
1
Character
E
R
02h
45h
34h
30h
4
0
52h
32h
INF - 16
Page of 23
Display