PT-DZ16KU, PT-DZ16KE, PT-DS16KD (serv.man5) - Panasonic Projector Other Service Manuals (repair manual). Page 11

Read Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man5) Other Service Manuals online

SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
  9. MODEL
Set this when the A-P.C.Board is replaced.
  * If you can copy EEPROM data from the old A-P.C.Board, this setting is unnecessary.
  * This model setting is changed after turn power on and off.
10. CLOG SENSOR CALIBRATION
Proofreading the blocking detect circuit.
  * Execute this after EEPROM(IC3509/IC3518)/A-P.C.Board or clogging sensor (M2-P.C.Board) is replaced.
  * Please refer to Clause 1 of SECTION 3 (Adjustments) for the procedure.
11. LAMP COOLING MODE
Setting of the fan operation for lamp cooling time. 
 - FAN STOP : Lamp fan is stopped at the lamp cooling time.
 - FAN ROTATION : Lamp fan is rotated at the lamp cooling time.
12. SMOKE FILTER DISPLAY
Setting of the self-diagnosis display (U75) at the time of smoked cut-off filter use. 
  - ON : Warning is displayed.
  - OFF : Warning is not displayed.
    3. 3. 2. Additional function of each menu
  1. [PICTURE] menu
AI WINDOW」 is added to the setting of the sub menu "dynamic iris".
    - AI WINDOW: Sets the APL detection area. Please set AI MODE to "AUTO" usually.
  2. [POSITION] menu
DVI EQUALIZER」 is added to a sub menu.
    - DVI EQUALIZER: If noise appears when DVI input, sets the value so that the noise decreases.
      Please set to "AUTO" usually.
INF - 11
      Please set to  AUTO  usually.
  3. [DISPLAY OPTION] menu
The following items are added to setting of sub menu "SDI IN".
XYZ TO RGB SETTING」
    - FACTORY SETTING: Uses the value of FACTORY Yxy conversion factor to the original data of XYZ → RGB.
    (Default)
    - MEASURED: Uses the value of MEASURED Yxy conversion factor to the original data of XYZ → RGB.
    - REC709: Uses the value of REC709 Yxy conversion factor to the original data of XYZ  → RGB.
    - DCI P3: Uses the value of DCI P3 Yxy conversion factor to the original data of XYZ  → RGB.
XYZ TEST PATTERN」
    - WHITE:10%~100%
    - DARK GRAY:1~10
    - COLOR:Red/Green/Blue/Cyan/Magenta/Yellow    1~2
  4. [PROJECTOR SETUP] menu
MAX AVAILABLE LAMPS」 is added to a sub menu.
Sets the maximum number of lamps that can be used. Please set to "4" normally.
DETAILED INFORMATION」 is displayed by pressing the "ENTER" button on the  「BRIGHTNESS CONTROL」 screen.
The detailed information of brightness control can be checked. 
SHUTTER COUNTER」 is added to setting of the sub menu "INITIALIZE".
When the mechanical shutter is replaced, initialize the shutter counter.
The following items are added to an indication screen of the sub menu "STATUS ".
  1) Page 2
- BALLAST VERSION
Ballast software version
  2) Page 3
- HORIZONTAL TILT
Horizontal angle