SECTION 1 SERVICE INFORMATION
<PT-DZ16K>
5. SELF CHECK
Self-diagnosing information Displays.
SELF CHEC
①-
MAIN : R1.00
②-
SUB : R1.00
③-
NT : R1.00 / 1.00
④-
OK AIR TEMP 123/456 OK DMD TEMP 123/456
⑤-
OK OUT TEMP 123/456 OK AIR FLOW 123/456/789
⑥-
OK LAMP1 12345H 3OM ON
⑦-
OK LAMP2 12345H 3OM ON
⑧-
OK LAMP3 12345H 3OM ON
⑨-
OK LAMP4 12345H 3OM ON
⑩-
OK FAN 1111 1111 1111 1111 1111 11
⑪-
OK PHOTO SENSOR Y 12345.6
⑫-
OK ANGLE SENSOR H -12.34/V +56.78
⑬-
OK IRIS
⑭-
OK SHUTTER 12345 [ 0]
①-
Main microprocessor Software Version
②-
Sub microprocessor Software Version
③-
Network microprocessor Software Version (rootfs/kernel)
④-
Intake air temperature (Celsius/Fahrenheit)
DMD temperature (Celsius/Fahrenheit)
⑤-
Exhaust air temperature (Celsius/Fahrenheit)
Airflow sensor (Sensor value/AD conversion value
⑥-
LAMP1 condition (Cumulative usage time/ON-OFF)
/Correction value)
*
When the item from 4 to 14 is abnormal last time and shuts it down,
the font of OK becomes red.
INF - 10
⑥
(
g
)
)
⑦-
LAMP2 condition (Cumulative usage time/ON-OFF)
⑧-
LAMP3 condition (Cumulative usage time/ON-OFF)
⑨-
LAMP4 condition (Cumulative usage time/ON-OFF)
⑩-
Fan condition (1: normal /0:stop)
OK FAN
⑪-
Brightness sensor condition
⑫-
Angle sensor condition (Horizontal angle / Vertical angle)
⑬-
Iris Condition
⑭-
Shutter condition (Opening and shutting number of times [Failed number of times])
6. POWER OFF MESSAGE
Setting of the shutter function with standby operation
- SHUTTER KEEP: When push the standby key with shutter ON, keep the shutter mode.
- SHUTTER OPEN: When push the standby key with shutter ON, open the shutter and display
- SHUTTER KEEP: When push the standby key with shutter ON, keep the shutter mode.
- SHUTTER OPEN: When push the standby key with shutter ON, open the shutter and display
the "Power OFF confirmation message". (Default setting)
7. ERROR OSD
When do not watch the error instructions LED of the lamp by a back projection,
the errors of the lamp can be displayed in the OSD.
- ON: "Lamp error message" is displayed on OSD.
- OFF: Does not display the "Lamp error message" in OSD.
the errors of the lamp can be displayed in the OSD.
- ON: "Lamp error message" is displayed on OSD.
- OFF: Does not display the "Lamp error message" in OSD.
8. CONVERGENCE
When the ingredient of each R/G/B color deviation, revise it electrically.
Specifically, please refer to Clause 1 of SECTION 3 (adjustments).
Specifically, please refer to Clause 1 of SECTION 3 (adjustments).
E
xhaust
1
E
xhaust
2
E
xhaust
3
E
xhaust
4
Intake
1
Intake
2
Lamp
1
Lamp
2
Lamp
3
Lamp
4
Ba
lla
st
1
Ba
lla
st
2
Po
we
r
S
ignal
Lamp
R
Lamp
L
Co
lo
r p
rism
1
Co
lo
r p
rism
2
P
ump-R
ed
P
ump-Green
P
ump-B
lu
e
Co
lo
r p
rism
3
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1
1
INF - 10
Click on the first or last page to see other PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man5) service manuals if exist.