Bit
Factor
Description
61
20000000 00000000
PUMP1 error/warning
Cooling Pump-Red or pump drive circuit is failure
62
40000000 00000000
PUMP2 error/warning
Cooling Pump-Green or pump drive circuit is failure
63
80000000 00000000
PUMP3 error/warning
Cooling Pump-Blue or pump drive circuit is failure
64
00000000 00000001
Lamp error in portrait mode installation (noncompliant)
Normal lamp mounted in portrait mode installation 
65
00000000 00000002
Unsupported lamp warning
Portrait lamp mounted (DZ16K only)
66
00000000 00000004
Shutter error
It fails in the operation of the shutter
67
00000000 00000008
Dynamic iris error
It fail in the movement of the Iris
68
00000000 00000010
Lamp drive mode changeover error (noncompliant)
Lamp that was used for more than 10 hours
69
00000000 00000020
Unused
70
00000000 00000040
Unused
71
00000000 00000080
Unused
72
00000000 00000100
Lamp 1 memory error
73
00000000 00000200
Lamp 2 memory error
74
00000000 00000400
Lamp 3 memory error
75
00000000 00000800
Lamp 4 memory error
76
00000000 00001000
Unused
77
00000000 00002000
Unused
78
00000000 00004000
Unused
79
00000000 00008000
Unused
80
00000000 00010000
FPGA 1/2 configuration error
Signal unit is failure
81
00000000 00020000
FPGA 3 configuration error
Signal unit is failure
82
00000000 00040000
Unused
83
00000000 00080000
Unused
84
00000000 00100000
Unused
85
00000000 00200000
Unused
86
00000000 00400000
Lens mounter error
Stepping-motor is failure
Limit position detection sensor failure
87
00000000 00800000
Ballast1 communication error
Ballast1 communication error
88
00000000 01000000
Ballast2 communication error
Ballast2 communication error
89
00000000 02000000
Ballast3 communication error
Ballast3 communication error
90
00000000 04000000
Ballast4 communication error
Ballast4 communication error
91
00000000 08000000
Unused
Lamp memory has not been initialized
LO
WER
Error code (hex)
INF - 28
91
00000000 08000000
Unused
92
00000000 10000000
Unused
93
00000000 20000000
Unused
94
00000000 40000000
Unused
95
00000000 80000000
Installation angle warning
Tilted at an angle that exceeds ±15° from the horizontal
96
00000001 00000000
Unused
97
00000002 00000000
Network microcomputer communication error Network microcomputer no response
98
00000004 00000000
Sub microcomputer (R8) communication error Sub microcomputer no response
99
00000008 00000000
IIC communication error 1(RTC)
100
00000010 00000000
IIC communication error 2(EEPROM) 
101
00000020 00000000
IIC communication error 3(LAMP1 EEPROM) 
102
00000040 00000000
IIC communication error 4(LAMP2 EEPROM)
103
00000080 00000000
IIC communication error 5(LAMP3 EEPROM)
104
00000100 00000000
IIC communication error 6(LAMP4 EEPROM) 
105
00000200 00000000
IIC communication error 7(EDID DIGITAL) 
106
00000400 00000000
IIC communication error 8(EDID ANALOG) 
107
00000800 00000000
IIC communication error 9(ADC1) 
108
00001000 00000000
IIC communication error 10(ADC2) 
109
00002000 00000000
IIC communication error 11
(ACCELERATION SENSOR)
110
00004000 00000000
IIC communication error 12(OPTICAL SENSOR)
Luminance sensor error, Connector disconnection(M31/RL14)
111
00008000 00000000
Unused
112
00010000 00000000
Unused
113
00020000 00000000
Unused
114
00040000 00000000
Unused
115
00080000 00000000
Unused
116
00100000 00000000
Unused
117
00200000 00000000
Unused
118
00400000 00000000
Unused
119
00800000 00000000
Unused
120
01000000 00000000
Unused
121
02000000 00000000
Unused
122
04000000 00000000
FM-P.C.B communication error
Formatter communication error
123
08000000 00000000
WF-P.C.B(GEOMERTY) communication error GEOMETORY IC abnormal
124
10000000 00000000
Unused
125
20000000 00000000
Lamp mixed mounted warning
Portrait lamp and normal lamp mixed use
126
40000000 00000000
Unused
U
PPER
Appropriate device malfunction of signal unit
126
40000000 00000000
Unused
127
80000000 00000000
Internal error
Main microcomputer circuit is abnormal