Read Panasonic PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE Other Service Manuals online
DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
19
For PT-DZ13K series, PT-DZ8700 series
1. Clean up the surfaces of aperture unit and the DMD by using air blower or proper chemical cleaner.
2. Attache the interposer on the DMD chip on the aliment plate.
3. Mount the DMD aperture unit on the alignment plate with 2 screws-E.
E
Alignment plate
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Ellipse hole side
(Torque: 22±2 N•cm)
DMD Aperture
Aperture
holder
Wide cut-
ting part
Ellipse hole side
E
E
Click on the first or last page to see other PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE service manuals if exist.