PT-DS100XE, PT-DS12KE, PT-DS20K2E, PT-DS20K2EJ, PT-DS20KE, PT-DW11KE, PT-DW17K2E, PT-DW17KE, PT-DW90XE, PT-DZ10KE, PT-DZ110XE, PT-DZ13KE, PT-DZ16K2E, PT-DZ16KE, PT-DZ21K2E, PT-DZ21KE, PT-RQ13KE, PT-RQ22KEJ, PT-RQ32KE, PT-RS11KE, PT-RS30KE, PT-RZ12KE, PT-RZ21KE, PT-RZ31KE - Panasonic Projector Other Service Manuals (repair manual). Page 18

Read Panasonic PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE Other Service Manuals online

DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
18
E
Alignment plate
Heat conductive sheet*
(only for G-DMD)
* PT-DZ21K series do not pro-
vide this sheet.
Aperture holder
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Aperture dustproof
Dustproof sheet
Wide cut-
ting part
Ellipse hole side
For PT-RZ31K series,  PT-RZ21K series, PT-DZ21K2 series, PT-DZ21K series
1. Stick the heat conductive sheet on the alignment plate. (G-DMD only)
2.  Clean up the surfaces of aperture dustproof and the DMD by using air 
blower or proper chemical cleaner.
3. Attache the interposer on the DMD chip on the aliment plate.
4.  Mount the DMD aperture unit on the alignment plate with 2 aperture 
holders and 6 screws-E.
Page of 44
Display

Click on the first or last page to see other PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE service manuals if exist.