Read Panasonic PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE Other Service Manuals online
DMD chip, FM-PCB and TIR prism Replacing Procedure
DMD chip, FM-PCB and TIR prism Replacing Procedure
17
4. Mount the DMD chip on the alignment plate.
1. Set a new DMD chip on the alignment plate.
2. Apply the adhesive bond at 3 point as like as the original.
[Note]: It takes about 20 minutes or more for dry up the bond completely.
5. Mount the DMD aperture unit on the alignment plate.
E
Alignment plate
Interposer
DMD aperture unit
(Torque: 22±2 N•cm)
Adhesive bond :
3M [DP420] 0.025g
Adhesive bond
Aperture dustproof
Dustproof sheet
Wide cut-
ting part
Ellipse hole side
For PT-RZ12K series
1. Clean up the surfaces of aperture dustproof and the DMD by using air
blower or proper chemical cleaner.
2. Attache the interposer on the DMD chip on the aliment plate.
3. Mount the DMD aperture unit on the alignment plate with 2 screws-E.
Click on the first or last page to see other PT-DS100XE / PT-DS12KE / PT-DS20K2E / PT-DS20K2EJ / PT-DS20KE / PT-DW11KE / PT-DW17K2E / PT-DW17KE / PT-DW90XE / PT-DZ10KE / PT-DZ110XE / PT-DZ13KE / PT-DZ16K2E / PT-DZ16KE / PT-DZ21K2E / PT-DZ21KE / PT-RQ13KE / PT-RQ22KEJ / PT-RQ32KE / PT-RS11KE / PT-RS30KE / PT-RZ12KE / PT-RZ21KE / PT-RZ31KE service manuals if exist.