Read Panasonic PT-AE700U / PT-AE700E Service Manual online
2.2 EXT OPTION Menu and Functions
TOP
PREVIOUS
NEXT
●
FREEZE MSG
Switching ON/OFF "FREEZE" on-screen display
●
PIC.SHIFT
Switching ON/OFF the antipersistence function
❍
Shifts the picture slightly (by one dot) when every 60 minutes. (one dot shifting three
times, one dot shifting three times in reverse direction, and repeats them alternately.)
times, one dot shifting three times in reverse direction, and repeats them alternately.)
●
RUNTIME PRT
Switching ON/OFF the shutdown when the operation time for the lamp unit is 2 000 hours or
longer
longer
●
FAN CONTROL
Setting the cooling fan motor rotation speed
❍
Switching ON "FAN FULLMODE", the rotation level of the fan becomes high-speed
rotation (fixed). Moreover, when "FAN FULLMODE" is ON, changing "FAN
CONTROL" in OPTION becomes impossible (setting FAN FULLMODE is given
priority more than FANCONTROL).
rotation (fixed). Moreover, when "FAN FULLMODE" is ON, changing "FAN
CONTROL" in OPTION becomes impossible (setting FAN FULLMODE is given
priority more than FANCONTROL).
●
AUTOSETUP
Setting AUTO SETUP mode