Read Panasonic PT-AE700U / PT-AE700E Service Manual online
1.2 Leakage Current Check
TOP
PREVIOUS
NEXT
1. Prepare the measuring circuit as shown in Fig.1.
Be sure to use a voltmeter having the performance described in Table 1.
Fig. 1
Table 1
Fig. 2
2. Assemble the circuit as shown in Fig. 2. Plug the power cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the voltage.
4. Change the connection of M1 from T1 to T2 and measure the voltage again.
Click on the first or last page to see other PT-AE700U / PT-AE700E service manuals if exist.