  5. 3. Firmware update procedure
1. Turn on the power of Multi Window Processor. (Power indicator will light in green.)
2. Connect the Multi Window Processor to the control computer using a USB cable.
3. Removable Disk "MWP100" will appear in My Computer on the PC.
    Click the removable disk "MWP100" and open.
4. Please copy a version upgrade file(Mxxx_yyy.dat/PLSBOOT) to the route of a removal disk. (overwrite) 
5. Please right-click on the icon of a removable disc after the completion of a copy, and perform removal of connection. 
    After that, please disconnect the USB cable.
6. Connect the Multi Window Processor to the control computer using a RS-232C cable.
[Note]
Where a USB cable is connected, communication by RS-232C can not be performed. 
Computer 
MWP100 
USB cable 
Computer 
MWP100 
RS-232C cable (Streight) 
Communication conditions 
 for the <RS232> terminal 