DP-MB545, DP-MB537, DP-MB536, DA-FAP109, DA-FAP110 - Panasonic Copying Equipment Service Manual (repair manual). Page 126

Read Panasonic DP-MB545 / DP-MB537 / DP-MB536 / DA-FAP109 / DA-FAP110 Service Manual online

126
DP-MB545/537/536 series
573
Remote turn-on ring number set
X number of rings
00~99
RU : 0
Others : 10
Sets the number of rings before the unit starts to
operate TAM in the TEL mode.
574
Dial tone detect check
1: ON
2: OFF
1, 2
OFF
 ---------- 
590
FAX auto redial time set
X number of 
times
00~99
RU : 03
TW, LA, 
AG : 02
Others : 05
Selects the number of redial times during FAX com-
munication (not including the first dial).
591
FAX auto redial line disconnection
time set
X sec
001~999
CX, SX : 
185
Others : 
065
Sets the FAX redial interval during FAX communi-
cation.
592
CNG transmit select 
1: OFF
2: ALL
3: AUTO
1~3
ALL
Lets you select the CNG output during FAX trans-
mission. ALL: CNG is output at phase A. AUTO:
CNG is output only when automatic dialing is per-
formed. OFF: CNG is not output at phase A. Refer
to  Sometime There is a Transmit Problem
(P.184).
593
Time between CED and 300bps
1: 75msec
2: 500msec
3: 1sec
1~3
75msec See How To Output The Journal Report (P.191)
and Receive Problem (P.185).
594
Overseas DIS detection select
1: detects at the 
1st time
2: detects at the 
2nd time
1, 2
detects at 
the
1st time
See How To Output The Journal Report (P.191)
and  Sometime There is a Transmit Problem
(P.184).
595
Receive error limit value set
1: 5%
2: 10%
3: 15%
4: 20%
1~4
10%
If the number of errors during transmission exceeds
this value, the sending side terminates the call.
596
Transmit level set 
X dBm
-15~00
TW : -11
Others :-
10
Selects the FAX transmission level. Refer to Some-
time There is a Transmit Problem
 (P.184) and
Receive Problem (P.185).
598
Receiving sensitivity 
43= -43dBm
20~48
48dBm
Used when there is an error problem. Refer to How
To Output The Journal Report
 (P.191).
599
ECM frame size 
1: 256
2: 64
1, 2
256
 ---------- 
628
H.V.P.S. check
See Test Functions (P.119).
639
LSU test
See Test Functions (P.119).
655
Cause Distinction Code of Call Ser-
vice 3
See  CALL SERVICE Troubleshooting Guide
(P.152).
673
Busy tone detection during FAX
transmission
1: ON
2: OFF
1,2
RU, TW : 
ON
( Others : 
Invalid )
677
FAN test
See Test Functions (P.119).
710
Memory clear except History data
Refer to Memory Clear Specification (P.127).
711
Dialing mode
1: PULSE
2: TONE
1,2
RU : 
PULSE
Others 
:TONE
717
Transmit speed select
1: 14,400bps
2: 12,000bps
3: 9,600bps
4: 7,200bps
5: 4,800bps
6: 2,400bps
1~6
14,400bps If the code 527 is set at 1, the code 717 and 718
work.
718
Receive speed select 
1: 14,400bps
2: 12,000bps
3: 9,600bps
4: 7,200bps
5: 4,800bps
6: 2,400bps
1~6
14,400bps If the code 527 is set at 1, the code 717 and 718
work.
721
Pause tone detect 
1: ON 
2: OFF
1, 2
OFF
Selects the tone detection for pause in dialing.
722
Redial tone detect 
1: ON
2: OFF
1, 2
LA, AG : 
OFF
Others : 
ON
Sets the tone detection mode after redialing.
Code
Function
Set Value
Effective 
Range
Default
Remarks
Page of 127
Display