Read Panasonic DP-MB545 / DP-MB537 / DP-MB536 / DA-FAP109 / DA-FAP110 Service Manual online
119
DP-MB545/537/536 series
10 Test Mode
10.1. Test Functions
The codes listed below can be used to perform simple checks of some of the unit’s functions. When complaints are received
from customers, they provide an effective tool for identifying the locations and causes of malfunctions.
from customers, they provide an effective tool for identifying the locations and causes of malfunctions.
Test Mode
Type of Mode
Code
Function
Operation after code
input
MEMORY CLEAR
Service Mode
“5” “5” “0”
Clear the memory where the users can store data.
SET
MOTOR TEST
Service Mode
“5” “5” “6”
00:printer motor feed 10:auto document feed 20:carriage
SET
MODEM TEST
Service Mode
“5” “5” “4”
Telephone line circuit is connected automatically, output the following signals on
the circuit line.
1) OFF 2) 1,100Hz 3) 2,100Hz 4) ANSam 5) CI
6) V21 300bps 7) V27 2,400bps 8) V27 4,800bps
9) V29 7,200bps 10) V29 9,600bps 11) V17 7,200bps 12) V17 9,600bps
13) V17 12,000bps 14) V17 14,400bps 15) V34 2,400bps 16) V34 4,800bps
17) V34 7,200bps 18) V34 9,600bps 19) V34 12,000bps 20) V34 14,400bps
21) V34 16,800bps 22) V34 19,200bps 23) V34 21,600bps
24) V34 24,000bps 25) V34 26,400bps 26) V34 28,800bps
27) V34 31,200bps 28) V34 33,600bps
the circuit line.
1) OFF 2) 1,100Hz 3) 2,100Hz 4) ANSam 5) CI
6) V21 300bps 7) V27 2,400bps 8) V27 4,800bps
9) V29 7,200bps 10) V29 9,600bps 11) V17 7,200bps 12) V17 9,600bps
13) V17 12,000bps 14) V17 14,400bps 15) V34 2,400bps 16) V34 4,800bps
17) V34 7,200bps 18) V34 9,600bps 19) V34 12,000bps 20) V34 14,400bps
21) V34 16,800bps 22) V34 19,200bps 23) V34 21,600bps
24) V34 24,000bps 25) V34 26,400bps 26) V34 28,800bps
27) V34 31,200bps 28) V34 33,600bps
SET
ROM CHECK
Service Mode
“5” “5” “1”
Indicates the version and checks the sum of the ROM.
SET
LCD TEST
Service Mode
“5” “5” “8”
Checks the LCD indication.
Illuminates all the dots to check if they are normal.
Illuminates all the dots to check if they are normal.
SET
DTMF SINGLE
TONE TEST
TONE TEST
Service Mode
“5” “5” “2”
Outputs the DTMF as single tones. Used to check the frequencies of the individ-
ual DTMF tones. Refer to DTMF Single Tone Transmit Selection (P.121).
ual DTMF tones. Refer to DTMF Single Tone Transmit Selection (P.121).
1....ON
2....OFF
LED TEST
Service Mode
“5” “5” “7”
All LEDs above the operation panel board flash on and off, or are illuminated.
KEY TEST
Service Mode
“5” “6” “1”
Checks the button operation.
Indicates the button code on the LCD while the button is pressed.
Indicates the button code on the LCD while the button is pressed.
START (any key)
SCANNER TEST
Service Mode
“5” “5” “5”
LED lights up, Scanner scanning.
1:RED / 2:GREEN / 3:BLUE / 4:monochrome / 5:Color
1:RED / 2:GREEN / 3:BLUE / 4:monochrome / 5:Color
LSU TEST
Service Mode
“6” “3” “9”
Laser radiates, Polygon rotates
SET
High Voltage Power
Supply Board
CHECK
Supply Board
CHECK
Service Mode
“6” “2” “8”
SET
FAN TEST
Service Mode
“6” “7” “7”
01:TEST OFF
02:FAN 1 High-speed rotation / FAN 2 STOP
03:FAN 1 Low-speed rotation / FAN 2 STOP
04:FAN 1 STOP / FAN 2 High-speed rotation
05:FAN 1 STOP / FAN 2 Low-speed rotation
06:FAN 1 STOP / FAN 2 STOP
07:FAN 1 High-speed rotation / FAN 2 Low-speed rotation
08:FAN 1 Low-speed rotation / FAN 2 High-speed rotation
09:FAN 1 Low-speed rotation / FAN 2 Low-speed rotation
10:FAN 1 High-speed rotation / FAN 2 High-speed rotation
02:FAN 1 High-speed rotation / FAN 2 STOP
03:FAN 1 Low-speed rotation / FAN 2 STOP
04:FAN 1 STOP / FAN 2 High-speed rotation
05:FAN 1 STOP / FAN 2 Low-speed rotation
06:FAN 1 STOP / FAN 2 STOP
07:FAN 1 High-speed rotation / FAN 2 Low-speed rotation
08:FAN 1 Low-speed rotation / FAN 2 High-speed rotation
09:FAN 1 Low-speed rotation / FAN 2 Low-speed rotation
10:FAN 1 High-speed rotation / FAN 2 High-speed rotation
MEMORY CLEAR
(except History data)
(except History data)
Service Mode
“7” “1” “0”
Refer to Memory Clear Specification (P.127).
SET
PRINT TEST PAT-
TERN
TERN
Service Mode
“8” “5” “2”
1. Press “852” then the SET key in the service mode.
2. As “PATNO. =” is displayed on the LCD, enter the test pattern No. and press
the SET key.
3. When “NO. = “is displayed on the LCD, enter the printing number and press the
SET key. (Press “00” for the infinite printing.)
4. “MODE=” is displayed on the LCD. Press “0” to start printing or press “1” to go
to the next screen.
5. When “1” is pressed at MODE, “INTVL = “is displayed on the LCD. Enter the
printing interval (000~999 sec).
6. The printing repeats the designated number of times at the programmed print-
ing intervals.
Refer to Print Test Pattern (P.122).
2. As “PATNO. =” is displayed on the LCD, enter the test pattern No. and press
the SET key.
3. When “NO. = “is displayed on the LCD, enter the printing number and press the
SET key. (Press “00” for the infinite printing.)
4. “MODE=” is displayed on the LCD. Press “0” to start printing or press “1” to go
to the next screen.
5. When “1” is pressed at MODE, “INTVL = “is displayed on the LCD. Enter the
printing interval (000~999 sec).
6. The printing repeats the designated number of times at the programmed print-
ing intervals.
Refer to Print Test Pattern (P.122).
Click on the first or last page to see other DP-MB545 / DP-MB537 / DP-MB536 / DA-FAP109 / DA-FAP110 service manuals if exist.