501
Pause time set 
X 100msec
001~600
3 sec
 ---------- 
503
Dial speed select 
1: 10pps 
2: 20pps
1, 2
10 pps
 ---------- 
507
V34 transmission start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
33,600bps If the code 527 is set at 2, the code 507 and 508
work.
508
V34 reception start speed 
0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8
33,600bps If the code 527 is set at 2, the code 507 and 508
work.
514
Bell signal detect time 
X 100msec
1~9
JT, EU : 
300ms
Others : 
600ms
 ---------- 
520
CED frequency select
1: 2,100Hz
2: 1,100Hz
1, 2
2,100Hz See How To Output The Journal Report (P.191).
521
International mode select 
1: ON
2: OFF
1, 2
EU : OFF
Others : 
ON
See How To Output The Journal Report (P.191).
522
Auto standby select
1: ON
2: OFF
1, 2
ON
The resolution reverts to the default when transmis-
sion is complete.
523
Receive equalizer select
1: 0km
2: 1.8km
3: 3.6km
4: 7.2km
1~4
0km
Set RX equalizer to automatic mode.
524
Transmission equalizer select 
1: 0km
2: 1.8km
3: 3.6km
4: 7.2km
1~4
0km
527
V.8 function select 
1: OFF
2: ON
1, 2
ON
529
Call Service Clear
550
Memory clear
Refer to Memory Clear Specification (P.127).
551
ROM check
See Test Functions (P.119).
552
DTMF signal tone test
1: ON
2: OFF
1, 2
OFF
See Test Functions (P.119).
553
Monitor on FAX communication
select 
1: OFF   
2: Phase B
3: ALL
1~3
OFF
Sets whether to monitor the line signal with the
unit's speaker during FAX communication or not.
554
Modem test
See Test Functions (P.119).
555
Scanner test
See Test Functions (P.119).
556
Motor test
See Test Functions (P.119).
557
LED test
See Test Functions (P.119).
558
LCD test
See Test Functions (P.119).
561
KEY test
See Test Functions (P.119).
565
Irregular data set
1: Non-Delete
2: Delete
1,2
Non-delete Sets whether delete Caller ID irregular data or not.
567
T0 timer
X sec
001~255
RU : 29 
sec
Others : 52 
sec
Sets a higher value when the response from the
other party needs more time during automatic FAX
transmission.
570
BREAK% select
1: 61%
2: 67%
3: 63%
1, 2, 3
TW, AG : 
67%
Others : 
61%
Sets the% break of pulse dialing according PBX.
Page of 127