DP-2310, DP-23010 - Panasonic Copying Equipment Service Manual (repair manual). Page 93

Read Panasonic DP-2310 / DP-23010 Service Manual online

93
DP-2310/3010
APR 2003
Ver. 1.00
Repeat the above steps if there are additional firmware code files to be updated.
Confirm that the update was successfully completed by checking the Firmware Version with F9 
Parameters F9-02-xx.
Caution:
If the unit does not boot up properly in step 8, refer to 3.7.8. (Firmware Emergency Recovery)
3.7.5.
Creating a Master Firmware Card
A. Utilizing the Firmware Update Kit
1) Install the Local Firmware Update Tool to your PC
The option CD-ROM or the Panasonic Document Management System CD-ROM includes the Local 
Firmware Update Tool and the Main Unit Firmware Code are located in the Option CD-ROM only. 
Please refer to the following Operating Instructions to install the Local Firmware Update Tool.
Operating Instructions:
\xFirmware\Tools\Firmup\FIRMUP OI.pdf (Refer to the 
Local Firmware Update Tool OI
 on the CD)
Setup:
\xFirmware\Tools\Firmup\Setup\Setup.exe
2) Preparing the Firmware Code
Double click the appropriate Destination Shortcut Batch File and copy the Firmware Code File on the 
CD ROM to the Firmware Data Folder in your PC. Note that the files in the Archive will be extracted 
automatically into the designated folder when the Archived file (.exe) is Double-clicked.
Example:
From:
Destination Shortcut Batch File:  D:(CD-ROM Drive) \ xFirmware \ USA.bat
Firmware Code File:
DP-2310_3010_xx_xxxxxx.exe
To:
Firmware Data Folder: 
C:\ Panasonic \ Panasonic-FUP \ Data
3) Preparing the Main Unit for the Programming Master Firmware Card
Important: DO NOT connect the USB Cable yet.
1. Turn the Power Switch on the left side and the Main Power Switch on the back of the machine to the 
OFF position. (See 3.7.7.)
2. Insert/Remove the Flash Memory Card (4 MB or 8 MB) into/from the machine.
3. Turn the Main Power Switch on the back and the Power Switch on the left side of the machine to the 
ON position.
4. Press the "FUNCTION”, “ORIGINAL SIZE (LEDGER/A3)" and “3” keys simultaneously in that order 
to enter the Service Mode.
5. Perform the Update Program Card Mode F9-09 (Update Program Card).
The unit is now ready to accept the firmware code from the USB Port.
Now connect the USB Cable between the Unit and PC. 
(Refer to the Local Firmware Update Tool OI on the CD)
Repeat the above steps if there are additional master firmware cards to be programmed.