NR-BN30PGW, NR-BN30PGB, NR-BN30PS1, NR-BN30QGW, NR-BN30QGB, NR-BN30QW1, NR-BN30QS1 - Panasonic Other Service Manuals Service Manual (repair manual). Page 27

Read Panasonic NR-BN30PGW / NR-BN30PGB / NR-BN30PS1 / NR-BN30QGW / NR-BN30QGB / NR-BN30QW1 / NR-BN30QS1 Service Manual online

 
 
27 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                        Hardware Self-test Procedure
 
1.  Press the "OK" button and the "Fridge" button at same time for 
more than 3 seconds to enter the hardware self-test 
procedure. Initially, the buzzer will beep and then all LED 
segments will be turned on. After 2 sec., all LED segments will 
be turned off. 
2.  Test temperature sensor 
a.  Test the interface of the refrigerating compartment 
sensor. If normal (standard resistance +5
C), then the 
refrigerating display will read "P0". If it fails, then "E0" 
will be displayed.   
b.  Test the interface of the freezing compartment sensor. If 
normal (standard resistance -17
C), then the freezing 
compartment display will read "P0". If it fails, then "E0" 
will be displayed. 
c.  Test the interface of the freezer evaporator. If normal 
(standard resistance -17
C), 
                                        then the refrigerating compartment display will read         
                                      "P0". If it fails, then "E1" will be displayed. 
a.  In the event of any fault during the above test, the fault 
code will flicker and the self-test will stop. 
2.  After pressing the "refrigerating" key, all segments on the LED 
screen will turn on. The master control panel will test loads one 
by one. 
a.  The compressor control relay turns on and off twice at 
the frequency of 2Hz. 
b.  The freezer fan is on for 2s. 
c.  The freezer defrosting heater is on for 2s. 
d.  The electric air vent is fully opened and immediately 
closed. 
e.  The light is on for 2s. 
3.  After test is over, the buzzer will sound for 1s and the 
equipment will return to its normal operation.   
4.  The maximum operation duration of the hardware self-test 
procedure is 10 minutes. 
Page of 40
Display