NR-BN30PGW, NR-BN30PGB, NR-BN30PS1, NR-BN30QGW, NR-BN30QGB, NR-BN30QW1, NR-BN30QS1 - Panasonic Other Service Manuals Service Manual (repair manual). Page 22

Read Panasonic NR-BN30PGW / NR-BN30PGB / NR-BN30PS1 / NR-BN30QGW / NR-BN30QGB / NR-BN30QW1 / NR-BN30QS1 Service Manual online

 
 
22 
1) Temperature is set improperly 
 
a) The temperature control knob is set to the "coldest" position. This position is to be used for fast 
freezing or continuous running, its temperature for power off is too low, therefore, the compressor 
won't stop and the temperature in the refrigerator becomes lower and lower . 
 
b) Inspection method: check the temperature control knob to see whether it is set in the position 
"coldest". 
 
2) Thermostat is malfunctioning and makes the compressor running continuously 
Analysis of Trouble 
When the thermostat doesn't work normally, it will make the compressor run continuously, and 
hence very low temperature will be achieved in the refrigerator. The fault is generally due to the fact 
that the contacts of the thermostat cannot be released. 
Remedy 
Dismantle the thermostat and make a through checkup, if it is totally out of functioning, replace it 
with a new one. 
 
3) Evaporation temperature is too high in refrigerating system, resulting in lower refrigerating 
capacity and hence continuous running of compressor 
Analysis of Trouble 
Leakage of refrigerant and clogging in a refrigerating system will directly affect its refrigerating 
capacity. Due to the reduction in its refrigerating capacity, the refrigerator temperature cannot reach 
its rated value, the thermostat won't work, thus the compressor runs continuously. When the 
evaporation temperature in the system is too high, the temperature sensing agent in the 
temperature sensor is also hotter, therefore, the thermostat is unable to cut off the power supply to 
the compressor and stop it. 
Remedy 
If it has been found that the refrigerant in the system is insufficient in quantity, recharge it with 
refrigerant. In case clogging occurs, disassemble the part where it is blocked. If the evaporation 
temperature is too high, settle this problem with an appropriate quantity of refrigerant. 
 
4) No stoppage of compressor due to damaged heat-insulation layer inside case body and/or door 
seal Analysis of Trouble 
When the heat-insulation layer inside the case body deteriorates or the door seal is not closely 
touches the door frame, the temperature in the refrigerator will rise and makes the compressor 
running continuously. Remedy Check the heat-insulation layer for its damaged parts, repair it to 
improve its heat-insulation property. If the door has deformed or the door seal is not tightly sealed 
against the case body, repair them, respectively. 
 
5) Too much food is placed in the refrigerator, or is placed too densely, resulting in poor ventilation 
or poor conditions for temperature sensing, and hence no stoppage of the compressor. 
 
6) Too high ambient temperature, poorer ventilation and heat dissipation make the compressor 
running without stop. 
F. Electric leakage of refrigerator 
Page of 40
Display