D. Compressor won't start 
In case the compressor cannot be started, you must find out the origins of this trouble through 
checkup step by step, because probably there are many causes, including those electrical and 
mechanical. 
 
1) Inspect the power supply to see whether it is connected to the compressor circuit. 
Analysis of Trouble 
In case the compressor cannot be started, this will generally exhibit in the power supply circuit, for 
instance, power failure, poor contact of switch, and blown fuse. Make a comprehensive analysis of 
these phenomena, fine out its real cause and take correct measures to remove this trouble. 
Remedy 
 
a) Check the input power circuit to see whether where is voltage of the power supply, namely, the 
circuit which is connected to the knife switch. This can be determined with an avometer or a test 
pencil. If a blown fuse is found, ascertain and remove its cause, then replace it with a new one of the 
same specifications. 
 
b) Check the compressor accessories, including its thermal protector and relay. In case the thermal 
protector is damaged, the compressor cannot be powered on. If the relay is out of order, the motor 
will not run and hum sound can be heard from it after the compressor is turned on, in that case, shut 
it down immediately, otherwise, the motor windings will be 
burned out in case this condition lasts longer. 
 
c) Check the relay contacts and plugs to see if they are perfect and work reliably. Poor contact may 
cause the motor not running or humming. 
 
2) Check the circuit voltage to see whether it is normal. 
Analysis of trouble 
If the circuit voltage is obviously lower than its rated value, it will be difficult to start the motor, and a 
hum sound can be heard from it. 
Remedy 
Measure the voltage with a voltmeter, if it is really too low, give directions to the user for buying a 
stabilizer so as to step up the voltage, thus normal operation can be achieved. 
 
3) Check the thermal relay to see whether its contacts are closed. 
Analysis of Trouble 
The contacts of thermal relay sometimes may be open due to the leakage of temperature sensing 
agent from the temperature sensor. 
Remedy 
Remove the relay cover to check up its contacts, if they are open, this means that the original setting 
is not properly set or temperature sensing agent has leaked out of the temperature sensor. Try to 
turn the adjusting stem of this value in the direction of the lower temperature graduation, then check 
the contacts to see whether they are closed. If they are still not closed, dismantle the temperature 
sensing disc and then immerse it into warm water to see whether the contacts actuate, if not, it can 
be preliminarily determine that temperature sensing agent has leaked out, and it must be replaced 
with a new thermostat. 