10.3.8.
Adjustment
Item
Operation
Default
Remarks
Shading
1.Click “Shading” on the adjust menu.
2.Check the resolution ( 300dpi, 600dpi) and click “OK”.
3.Clean the conveyor, rollers, Scanning Glass (F) and (B) 
according to the message on the display.
And click “OK”.
4. Set Shading Sheet (Part No.: PJXC0330Z-J) on the Feed Tray
in landscape orientation.
5. And click “OK” to scan the Shading Sheet.
6. After “Finished Adjusting” message, click “OK” to return to
the adjust menu.
Until this process is 
completed, don't stop the 
process by opening any doors 
or turning off the scanner.
Shading data
1.Click “Shading data” on the adjust menu.
2. Click “Get Shading Data” on the Shading Data.
3. Save it to selected folder.
4. Click “OK” to return to the adjust menu.
This data file is used for 
analysis.
All position
1.Set 2 pcs of test chart A (Part No.: PBQX90095Z-J) on the 
Feed Tray in portrait orientation.
And set 1 pcs of test chart A on the Flatbed.
2. Click “All position” on the adjust menu to execute scanning
position and length adjustment.
3. Check the result.
4. Click “OK” to return to the adjust menu.
Set 2 pcs of test chart A on 
the Feed Tray in order.
  1st page: Front side
  2nd page: Back side
Individual position 1.Adjust Automatically.
a.Set test chart A (Part No.: PBQX90095Z-J) on the Feed Tray 
in portrait orientation.
b.Click “Individual position” on the adjust menu.
c.Click one of 6 “Adjust Automatically” buttons on the 
“Individual position” dialog box to execute the adjustment.
d.Check the result.
e.Click “OK” to finish the adjustment.
f.Click “OK” to return to the adjust menu.
2. Adjust Manually.
a.Click “Individual position” on the adjust menu.
b.Change the parameters (mm, %) on the “Individual
position” dialog box as required. (Refer to Remarks.)
c.Click “OK” to renew the setting, and to return to the adjust
menu.
1.Adjust Automatically  
automatic adjustments  items
a.Length
b.Paper End Position
c. Front V. Position
d. Front h. Position
e. Back V. Position
f. Back H. Position
2.Adjust Manually 
(Length)
+: Increasing the value 
allows the scanned 
image to extend 
vertically.
(Paper End Position)
+: On the LC (Length 
Control) mode, 
increasing the value 
allows the paper-end 
timing to be earlier.
(Vertical Position)
+: Increasing the value 
shifts the scanned image 
position downward.
(Horizontal Position)
+: Increasing the value 
shifts the scanned image 
position to the right.
Note
If the appropriate 
scanning position 
cannot be obtained by 
any of the manual 
adjustments, check CIS 
installation.