3. Slip Detect Sensor does not
work, correctly.
1. Execute “Key/Sensor” test in the Sec.
10.3.7. to check the sensor condition.
2. Check the mounting of the lens of the Slip
detect Sensor.
3. Check the following connection and
soldering condition on each connector.
soldering condition on each connector.
a. CN5140 (SLIP/STARTING SENSOR
Board) to CN3300 (LOWER RELAY
Board)
Board)
b. CN3304 (LOWER RELAY Board) to
CN18(CONTROL Board)
4. Check the following signals.
a. Slip detect Sensor signal (CN18-17th pin)
Approx. 5 V (paper exists)
b. Check the reference signal for the Slip
detect Sensor signal on the CONTROL
Board.
IC41-5th pin: Approx. 2.5 V
Board.
IC41-5th pin: Approx. 2.5 V
c. Check comparator output signal.
IC41-7th pin: 5.0 V
(no paper on the sensor)
(no paper on the sensor)
5. Replace faulty parts or boards.
4. Mechanical problem (Drive
Roller, Drive Belt, Conveyor)
1. Execute “Feed motor” and “Conveyor
motor” tests in Sec. 10.3.7. to check the
mechanical condition.
mechanical condition.
2. Check whether the Drive Rollers
(especially Drive Roller 1), the Drive belt, and
the conveyor to support the Drive Rollers are
put together into the scanner, properly.
3. Check the surfaces of the Drive Roller 1.
a. If it is deformed
(especially Drive Roller 1), the Drive belt, and
the conveyor to support the Drive Rollers are
put together into the scanner, properly.
3. Check the surfaces of the Drive Roller 1.
a. If it is deformed
Replace the roller.
b. If the surface is dirty
Clean the surface.
4. Check whether the Drive Belt tension is
proper.
Re-adjust the belt tension.
Re-adjust the belt tension.
5. Conveyor Motor does not work
properly.
1. Check the motor mechanism condition by
carrying out “Conveyor motor” test.
carrying out “Conveyor motor” test.
(See Sec. 10.3.7.)
2. Check the connection between the Conveyor
motor and CN2011 (DRIVE Board)
3. Try to exchange two of FFC cable between
the DRIVE Board and the CONTROL Board.
(If repaired, FFC cable breakage).
(If repaired, FFC cable breakage).
4. Replace Conveyor Motor.
6. Conveyor Motor circuit does not
work properly.
1. Check the following connection and
soldering on each connector.
CN15 (CONTROL Board) to CN2008
(DRIVE Board)
CN15 (CONTROL Board) to CN2008
(DRIVE Board)
2. Check the soldering of IC2014 and the
peripheral parts on DRIVE Board.
3. Check the following signals on the DRIVE
Board.
a. IC2014-12th pin (CLK): See Fig. 1.
b. IC2014-19th pin (VREF): 2.3V or less.
c. IC2014-15th pin (ENABLE): 3.3 V
(when executing Conveyor motor test)
a. IC2014-12th pin (CLK): See Fig. 1.
b. IC2014-19th pin (VREF): 2.3V or less.
c. IC2014-15th pin (ENABLE): 3.3 V
(when executing Conveyor motor test)
7. DFP Pressure Motor does not
work properly.
1. Check the motor mechanism condition by
carrying out “DFP pressure drive” test.
(See Sec. 10.3.7.)
(See Sec. 10.3.7.)
2. Check the connection between DFP Pres-
sure Motor and CN2016 (DRIVE Board)
3. Replace faulty cable.
4. Replace DFP Pressure Motor.
4. Replace DFP Pressure Motor.
Error Code
ST1 ST2 ST3 ST4
Possible Cause
Recommended action
Remarks