3. Slip Detect Sensor does not 
work, correctly.
1. Execute “Key/Sensor” test in the Sec. 
10.3.7. to check the sensor condition.
2. Check the  mounting of the lens of the Slip 
detect Sensor.
3. Check the following connection and
    soldering condition on each connector.
a. CN5140 (SLIP/STARTING SENSOR 
Board) to CN3300 (LOWER RELAY 
Board)
b. CN3304 (LOWER RELAY Board) to 
CN18(CONTROL Board)
4. Check the following signals.
a. Slip detect Sensor signal (CN18-17th pin)
Approx. 5 V (paper exists)
b. Check the reference signal for the Slip 
detect Sensor signal on the CONTROL 
Board.
IC41-5th pin: Approx. 2.5 V
c. Check comparator output signal.
IC41-7th pin: 5.0 V
 (no paper on the sensor)
5. Replace faulty parts or boards.
4. Mechanical problem (Drive 
Roller, Drive Belt, Conveyor)
1. Execute “Feed motor” and “Conveyor 
motor” tests in Sec. 10.3.7. to check the 
mechanical condition.
2. Check whether the Drive Rollers
    (especially Drive Roller 1), the Drive belt, and
    the conveyor to support the Drive Rollers are
    put together into the scanner, properly.
3. Check the surfaces of the Drive Roller 1.
      a. If it is deformed
          
 Replace the roller.
      b. If the surface is dirty
          
 Clean the surface.
4. Check whether the Drive Belt tension is 
proper.
 Re-adjust the belt tension.
5. Conveyor Motor does not work 
properly.
1. Check the motor mechanism condition by
    carrying out “Conveyor motor” test.
(See Sec. 10.3.7.)
2. Check the connection between the Conveyor 
motor and CN2011 (DRIVE Board) 
3. Try to exchange two of FFC cable between 
the DRIVE Board and the CONTROL Board. 
(If repaired, FFC cable breakage).
4. Replace Conveyor Motor. 
6. Conveyor Motor circuit does not 
work properly.
1. Check the following connection and 
soldering on each connector.    
 CN15 (CONTROL Board) to CN2008
     (DRIVE Board)
2. Check the soldering of IC2014 and the 
peripheral parts on DRIVE Board.
3. Check the following signals on the DRIVE 
Board.
a. IC2014-12th pin (CLK): See Fig. 1.
b. IC2014-19th pin (VREF): 2.3V or less.
c. IC2014-15th pin (ENABLE): 3.3 V 
     (when executing Conveyor motor test)
7. DFP Pressure Motor does not 
work properly.
1. Check the motor mechanism condition by 
carrying out “DFP pressure drive” test.
(See Sec. 10.3.7.)
2. Check the connection between DFP Pres-
sure Motor and CN2016 (DRIVE Board)
3. Replace faulty cable.
4. Replace DFP Pressure Motor.
Error Code
ST1 ST2 ST3 ST4
Possible Cause
Recommended action