Read Panasonic KV-S7075C (serv.man2) Service Manual online
109
10 TROUBLESHOOTING
10.1. Troubleshooting-1 (when no error message is displayed on PC)
Phenomenon
Possible Cause
Check Point
Remarks
No power
1. Power cord is not correctly inserted.
Insert the power cord correctly.
2. Cables in the scanner are not
connected properly. (especially around
POWER Board)
connected properly. (especially around
POWER Board)
Insert the cables properly.
Pay attention
when
reassembling
the scanner.
when
reassembling
the scanner.
3. FAN does not rotate.
1. Rotate the FAN, manually.
2. Check the connection between CN803
(on the POWER Board) and FAN.
3. Remove the FAN.
2. Check the connection between CN803
(on the POWER Board) and FAN.
3. Remove the FAN.
4. Power circuit (including a safety circuit)
does not work properly.
does not work properly.
1. Replace POWER Board.
5. LED (Indicators) or its drive circuit does
not work correctly.
not work correctly.
1. Check the following connections and
soldering condition on PANEL, DRIVE,
CENTER, and CONTROL Boards:
(1) CN1 (PANEL Board) to CN4003
(DRIVE Board)
(2) CN4004 (DRIVE Board) to CN2003
(CENTER Board)
(3) CN2001 (CENTER Board) to CN1001
(CONTROL Board)
2. Replace the PANEL Board.
3. Replace the DRIVE Board.
4. Replace the CENTER Board.
5. Replace the CONTROL Board.
soldering condition on PANEL, DRIVE,
CENTER, and CONTROL Boards:
(1) CN1 (PANEL Board) to CN4003
(DRIVE Board)
(2) CN4004 (DRIVE Board) to CN2003
(CENTER Board)
(3) CN2001 (CENTER Board) to CN1001
(CONTROL Board)
2. Replace the PANEL Board.
3. Replace the DRIVE Board.
4. Replace the CENTER Board.
5. Replace the CONTROL Board.
6. Boot program of this scanner does not
work correctly.
work correctly.
1. Check the soldering condition on
CONTROL Board.
2. Replace the CONTROL Board.
CONTROL Board.
2. Replace the CONTROL Board.
Click on the first or last page to see other KV-S7075C (serv.man2) service manuals if exist.