KV-S5055C (serv.man2) - Panasonic Other Service Manuals Service Manual (repair manual). Page 99

Read Panasonic KV-S5055C (serv.man2) Service Manual online

99
Individual Position 1. Adjust Automatically.
    a. Set test chart A (Part No.: See 14.8.) on the Hopper.
    b. Click “Individual Position” on the main menu.
    c. Click one of 8 “Adjust Automatically” buttons on the
        “Individual Position” dialog box to execute the
        adjustment.
    d. Check the result.
    e. Click “OK” to finish the adjustment.
     f. Click “OK” to return to the main menu.
2. Adjust Manually.
    a. Click “Individual Position” on the main menu.
    b. Change the parameter (mm,%) on the “Individual
        Position”
 dialog box as required. (Refer to Remarks.)
    c. Click “OK” to renew the setting, and to return to the
        main menu. 
1. “Adjust Automatically”
     a. Length
     b. Paper End Position
     c. Front Paper Width
     d. Front V. Position
     e. Front H. Position
     f. Back Paper Width   
     g. Back V. Position
     h. Back H. Position
 
2. Adjust Manually
   (Length)
    +: Increasing the number
        makes the scanning
        document length shorter.
  (Vertical Position)
     +: Increasing the number
         makes the document
         scanning position shifted
         upward.
  (Horizontal Position)
     +: Increasing the number
         makes the document
         scanning position shifted
          to the left.
  (Paper End Position)
     +: On the LC (Length
        Control) mode,
        increasing the number
        allows the paper-end
         timing to be earlier
 
   (Width)
      -: Decreasing the number
         extends the scanning
          document width.
Note
If the appropriate
scanning position can
not be obtained by any
of the manual
adjustments, check 
installation.
Item
Operation
Default
Remarks
Page of 127
Display