Read Panasonic KV-S5055C (serv.man2) Service Manual online
95
9.3.6.
Test
Item
Operation
Default
Remarks
LED
1. Click “LED” on the main menu.
2. Click “START” on “LED” dialog box to start LED Test
continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on “LED” dialog box to start LED Test
continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
—
Each indicator turns on or off
in a constant period.
in a constant period.
Key / Sensor
1. Click “Key / Sensor” on the main menu.
2. Check the key and sensor status on the “Key / Sensor”
dialog box.
2. Check the key and sensor status on the “Key / Sensor”
dialog box.
3. Click “Close” to return to the main menu.
—
Sensor Sensitive
Level
Level
1. Click “Sensor Sensitive Level” on the main menu.
2. Check each sensor’s sensitive level (Offset, Slice) on the
Sensor Sensitive Level dialog box.
3. Click “Close” to return to the main menu.
2. Check each sensor’s sensitive level (Offset, Slice) on the
Sensor Sensitive Level dialog box.
3. Click “Close” to return to the main menu.
—
Feed Motor
1. Click “Feed Motor” on the main menu.
2. Click “START” on the “Feed Motor” dialog box to start to
rotate Paper Feed Motor periodically controlled in the
paper-feed direction and its reverse direction until clicking
“STOP”.
Note:
2. Click “START” on the “Feed Motor” dialog box to start to
rotate Paper Feed Motor periodically controlled in the
paper-feed direction and its reverse direction until clicking
“STOP”.
Note:
• Rotating in the paper-feed direction will allow the Paper
Feed Roller Module to go down to perform the paper-feed
function.
• Rotating in the reverse direction will allow the Paper
Feed Roller Module to rise to perform the
paper-separation function.
Feed Roller Module to go down to perform the paper-feed
function.
• Rotating in the reverse direction will allow the Paper
Feed Roller Module to rise to perform the
paper-separation function.
3. Click “Close” to return to the main menu.
—
Conveyor Motor
1. Click “Conveyor Motor” on the main menu.
2. Click “START” on the “Conveyor Motor” dialog box to start
to rotate Conveyor Motor continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on the “Conveyor Motor” dialog box to start
to rotate Conveyor Motor continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
—
DFP Pressure
Drive
Drive
1. Click “DFP Pressure Drive” on the main menu.
2. Click “START” on “DFP Pressure Drive” dialog box to start
to rotate DFP Pressure Motor continuously until clicking
“STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on “DFP Pressure Drive” dialog box to start
to rotate DFP Pressure Motor continuously until clicking
“STOP”.
3. Click “Close” to return to the main menu.
—
Gate Drive
1. Click “Gate Drive” on the main menu.
2. Click “START” on the “Gate Drive” dialog box to start
to execute the open/close operation of the gate until clicking
“STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on the “Gate Drive” dialog box to start
to execute the open/close operation of the gate until clicking
“STOP”.
3. Click “Close” to return to the main menu.
—
Click on the first or last page to see other KV-S5055C (serv.man2) service manuals if exist.