9.3.7.
Adjustment
Item
Operation
Default
Remarks
Shading
1. Click “Shading” on the main menu.
2. Confirm the message “The data of User Shading will be
    also overwritten”
 on the display.
    And if the message is acceptable, click “OK”.
     Note:
  This procedure is avaiable only after executing User
  Shading. 
3. Clean the conveyor, rollers, Scanning Glass (F), and
     Scanning Glass (B) according to the message on the display.
     And click “OK”.
4. Reverse Reference Plates to white according to the message
    on the display.
    And click “OK”.
5. Set the accessory Shading Sheet or Shading Sheet
   (Part No.: See 14.8.) on the Hopper in landscape
    orientation.
6. And click “OK” to scan the Shading Sheet.
7. Reverse the Reference Plates to black according to the
    message on the display.
8. Click “OK” to return to the main menu.
Until this process is
completed, don’t stop the
process by opening any
doors or turning off the
scanner. 
All Position
1. Set 2 pcs of test chart A (Part No.: See 14.8.) on the Hopper
    in portrait orientation.
2. Click “All position” on the main menu to execute scanning
    position, length, width, and paper end adjustment. 
3. Check the result.
4. Click “OK” to return to the main menu.
Set 2 pcs of test chart A in
order.
 1st page: Front side
 2nd page: Back side
Page of 127