Read Panasonic KV-S1025C / KV-S1020C Service Manual Supplement online
14
5.3.4.
“Section 9.3.7 Adjust”
Item
Operation
Default
Remarks
Individual Position 1. Adjust Automatically
a. Set Test Chart A4 (Part No.: See 14.3.) on the Feed Tray
in the portrait orientation, according to
"1. Adjust Automatically" in the Remarks column.
b. Click “Individual Position” on the main menu.
c. Click one of 8 automatic adjustment menu on the
“Individual Position” dialog box to execute the
adjustment.
d. Check the result.
e. Click “OK” to finish this adjustment.
f. Click “OK” to get back to the main menu.
2. Adjust Manually
a. Click “Individual Position” on the main menu.
b. Change the parameter (mm, %) on the “Individual
Position” dialog box, as required. (Refer to Remarks.)
c. Click “OK” to apply the new setting, and to get back to the
main menu.
in the portrait orientation, according to
"1. Adjust Automatically" in the Remarks column.
b. Click “Individual Position” on the main menu.
c. Click one of 8 automatic adjustment menu on the
“Individual Position” dialog box to execute the
adjustment.
d. Check the result.
e. Click “OK” to finish this adjustment.
f. Click “OK” to get back to the main menu.
2. Adjust Manually
a. Click “Individual Position” on the main menu.
b. Change the parameter (mm, %) on the “Individual
Position” dialog box, as required. (Refer to Remarks.)
c. Click “OK” to apply the new setting, and to get back to the
main menu.
—
1. Adjust Automatically
8 automatic adjustment
(1) Adjust Length.
(2) Adjust Paper-end Position.
(3) Adjust Front Width.
(4) Adjust Front V. Position.
(5) Adjust Front H. Position.
(6) Adjust Back Width.
(7) Adjust Back V. Position.
(8) Adjust Back H. Position.
8 automatic adjustment
(1) Adjust Length.
(2) Adjust Paper-end Position.
(3) Adjust Front Width.
(4) Adjust Front V. Position.
(5) Adjust Front H. Position.
(6) Adjust Back Width.
(7) Adjust Back V. Position.
(8) Adjust Back H. Position.
(1) to (5): Face down the chart
on each individual
adjustment.
(6) to (8): Face up the chart on
each individual
adjustment
(KV-S1025C Series Only)
on each individual
adjustment.
(6) to (8): Face up the chart on
each individual
adjustment
(KV-S1025C Series Only)
2. Adjust Manually
(Length)
+:
(Length)
+:
Increasing the number
makes the scanning
document length shorter.
document length shorter.
(Paper End Position)
+: On the LC (Length Control)
mode, increasing a value
allows the paper-end timing
to be earlier.
(Width)
-:
+: On the LC (Length Control)
mode, increasing a value
allows the paper-end timing
to be earlier.
(Width)
-:
Decreasing the number
extends the scanning
document width.
document width.
(Vertical Position)
+:
+:
Increasing the number
makes the document
scanning position shifted
upward.
scanning position shifted
upward.
(Horizontal Position)
+:
+:
Increasing the number
makes the document
scanning position shifted
to the left
scanning position shifted
to the left
.
Note:
If the appropriate
scanning position can not
be obtained by any of the
manual adjustments,
check the Optical Unit
installation.
*USB ID
1. Click “USB ID” on the main menu to go into the USB ID
dialog box.
2. Click “Set” on the USB ID dialog box to store a new ID
number for a new replaced CONTROL Board.
3. Click “Close” to go back to the main menu.
dialog box.
2. Click “Set” on the USB ID dialog box to store a new ID
number for a new replaced CONTROL Board.
3. Click “Close” to go back to the main menu.
—
* This setting is available only
for a new replaced
CONTROL Board.
for a new replaced
CONTROL Board.
Click on the first or last page to see other KV-S1025C / KV-S1020C service manuals if exist.