5.3.
“Section 9.3 Operation”
This section describes each operation (or status indication), according to the function item list shown in Sec. 9.2.”
5.3.1.
“Section 9.3.1 Scanner Status”
This function indicates the scanner status, updating it every few seconds.
The status messages and their contents are as follows.
Fig. 9.3.1 Scanner Status
The status messages and their contents are as follows.
Fig. 9.3.1 Scanner Status
Classified Code
Status Message
Contents
—
Scanner has no error.
No error
U11/ U16/ U23
A paper jam or double feed has occurred.
Open the scanner’s door, remove the
documents, and close the door.
Place the documents back in the document
feed tray.
Open the scanner’s door, remove the
documents, and close the door.
Place the documents back in the document
feed tray.
Paper jam or double feed error
U18
Paper remains in the scanner.
Open the scanner’s door, remove the
documents, and close the door.
Place the documents back in the document
feed tray.
Open the scanner’s door, remove the
documents, and close the door.
Place the documents back in the document
feed tray.
Document remains in the scanner, there is
dust around a sensor, or the sensor
arm does not work properly.
dust around a sensor, or the sensor
arm does not work properly.
U30
Scanner Door is open!
Please close the door.
Please close the door.
ADF Door is open, or does not close tightly.
Or the door detection mechanism does not
work properly.
Or the door detection mechanism does not
work properly.
Fxx
System error occurred!
Please consult with a service representative.
Please consult with a service representative.
This type of error code requires a
Service-person's attention.
Service-person's attention.
—
***Caution***
The rollers need to be cleaned.
Please clean the rollers.
Please select “Clear Counter” button after
cleaning the rollers.
Please clean the rollers.
Please select “Clear Counter” button after
cleaning the rollers.
Caution message for cleaning
rollers
rollers
—
***Caution***
The replaceable rollers (consum-
able) are reaching the end of their
usable life.
To insure reliable operation,
please replace these rollers with
Roller Exchange Kit for your
specific scanner. After replacing
the roller, select the “Clear
Counter” button.
The replaceable rollers (consum-
able) are reaching the end of their
usable life.
To insure reliable operation,
please replace these rollers with
Roller Exchange Kit for your
specific scanner. After replacing
the roller, select the “Clear
Counter” button.
Caution message for replacing
rollers
rollers
—
*** Caution***
The inside of the scanner is dirty,
and requires routine cleaning.
To insure reliable scanning
quality, open the scanner's door,
and carefully clean the scanner's
conveyor and scanning glass
section.
The inside of the scanner is dirty,
and requires routine cleaning.
To insure reliable scanning
quality, open the scanner's door,
and carefully clean the scanner's
conveyor and scanning glass
section.
The scanning area is dirty.
—
Scanner is not connected!
Scanner is not connected to the PC
properly.
properly.