SR-TMJ181BTW - Panasonic Home Appliance Service Manual (repair manual). Page 10

Read Panasonic SR-TMJ181BTW Service Manual online

- 10 -
SR-TMJ181
4.3 Heat reserving test
The above conditions are proper.
1. Put approx. 1 liter of water and the thermometer [ repairing tool (mercury thermometer ASN-150H) ]
    in the pan, close the lid and turn on the boiling switch.
2. When the beings boiling to generate steam turn off the boiling switch.
Within 69°C - 77°C .....................................Proper 
If outside 69°C - 77°C, check triac mounting for irregularity, if it is proper, replace warming heater.
3. Add water or keep the lid opened until the reading of the thermometer falls to approx. 70°C.
4. When it becomes approx. 70°C, close the lid. After the warming heater is activated for 1 hour or more,
    check the heat reserving temperature. 
Top view of pan
Holes on the
tissue paper
Pan flange
Tissue paper
Mercury thermometer
Urethane foam blocks
Mercury thermometer
Inner Pan
Page of 16
Display

Click on the first or last page to see other SR-TMJ181BTW service manuals if exist.