Read Panasonic SR-PE55LTQ Service Manual online
7
5. Test Mode
Check whether the heater, sensor, inner pot, pot cover and seal ring are free from hit, deformation, damage or stuck
with foreign material, etc., whether the pressure relief valve is not clogged and whether the pressure indicator base
is not covered with foreign materials or dust. Please perform the test in a place where the cooker body is subject to
neither wind nor vibration.
with foreign material, etc., whether the pressure relief valve is not clogged and whether the pressure indicator base
is not covered with foreign materials or dust. Please perform the test in a place where the cooker body is subject to
neither wind nor vibration.
5.1 Test items without fi nished pressure relief valve in position
(at 1hPa=atmospheric pressure)
Items
Steps
Inspection items
Micro switch
1. Press the “Pressure Selection” key and
select high pressure.
2. Set any time and press the “Cooking
Startup” key.
3. Put in and take out the inner pot in
cooking.
• The “U10” indicator light fl ashes on the
LCD. See the items listed in the “Operation
Confi rmation of Pot Cover Detector”.
If the “U10” indicator light does not fl ash,
please check the safety microswitch.
Confi rmation of Pot Cover Detector”.
If the “U10” indicator light does not fl ash,
please check the safety microswitch.
Foaming
1. Pour about a cup of water (180ml) into
the inner pot, put the pot cover with
no hammer on carefully, and set the
condition to cooking.
no hammer on carefully, and set the
condition to cooking.
• If steam overfl ows from the nozzle, please take
off the pot cover and check the bubbling state
immediately, as shown in the diagram below.
immediately, as shown in the diagram below.
Foaming
Good
Poor
• The bubbling appears in circle .................Good
The bubbling does not appear at 1/4 or more
of the circle ................................................Poor
If poor, there may be some problem at the
contact area of the pot bottom and the bottom
heater.
Please remove foreign objects or replace
relevant component if necessary.
of the circle ................................................Poor
If poor, there may be some problem at the
contact area of the pot bottom and the bottom
heater.
Please remove foreign objects or replace
relevant component if necessary.
Timer operation
1. Pour out the heat water in the pot.
2. Place the pot cover without the fi nished
2. Place the pot cover without the fi nished
pressure relief valve on the pot carefully.
3. Set the cooking time at 2 min.
• After energization, the duration from buzzer
sounding to switching to thermal insulation
delays.
3 min + 40s
delays.
3 min + 40s
................................................
Good
Others
..........................................................
Poor
If poor, please replace the control panel (whole).
IP4749_SR_PE45_PE55_Eng_07_140314.indd 7
IP4749_SR_PE45_PE55_Eng_07_140314.indd 7
2014-3-14 9:12:39
2014-3-14 9:12:39