SD-ZP2000KTS - Panasonic Home Appliance Service Manual (repair manual). Page 13

Read Panasonic SD-ZP2000KTS Service Manual online

1
3
5.1.4.
  High temperature alarm mode
When the "Start" key is pressed when the unit is in the hot con-
dition at a temperature of more than 40 deg.C, the 
buzzer
 sounds, the LED turns OFF and the other load goes off 
in
 this mode.
* The high temperature alarm mode does not occur at the
"BAKE ONLY" menu rebaking setting.
Behaviour of restoration from high temperature alarm
mode
• When the unit temperature is less than 40 deg.C, and more
than 10 seconds passes after the high temperature alarm
mode has begun, the buzzer sounds once and the high tem-
perature alarm mode is canceled. (No indication on LCD)
Load control
• LED indication: 
OFF
• LCD indication: 
ON
• Buzzer information:
- Error buzzer rumbling at the time of "U50" starts.
- Cancellation buzzer rumbling in a Stop key receptionist.
- When I satisfied "the end condition - others" mentioned
above, a receptionist buzzer rumbles.
• Heater: OFF
• Motor: OFF
• Stop key: Become the setting state before becoming "U50".
• Become the setting state before becoming "U50" after
progress more than ten seconds after displaying "U50" if a
sensor becomes less than 40 degrees Celsius.
Indication on LCD
• "U50" is displayed on LCD. ("U50" is brinking)
Page of 32