SD-ZP2000KTS - Panasonic Home Appliance Service Manual (repair manual). Page 12

Read Panasonic SD-ZP2000KTS Service Manual online

1
2
5.1.2.
  Room temperature sensor disconnection mode
• When the disconnection of a sensor is detected, all load of
the device goes off in this mode.
Load control
• LED indication: 
OFF
• LCD indication: 
ON
• Buzzer information: OFF
• Heater: OFF
• Motor: OFF
• Room temperature sensor(TH1) detection temperature
except the disconnection when is in a condition, it is with
"wait mode - function choice - fault choice".
At this time, 
LCD display "H01" if a sensor is snapped.
Indication on LCD
• "H02" is displayed on the LCD during the sensor disconnec-
tion. ("H02" is brinking)
5.1.3.
  Temperature sensor disconnection and circuit short mode
• When the disconnection 
or circuit short of a sensor is
detected, all load of
 the device goes off in this mode.
Load control
• LED indication: 
OFF
• LCD indication: 
ON
• Buzzer information: OFF
• Heater: OFF
Motor: OFF
Sensor detection temperature except the disconnection or 
circuit short when is in a condition, it is with "wait mode- 
function choice - fault choice".
 Indication on LCD
• "H01" is displayed on the LCD during the sensor disconnec-
tion. ("H01" is brinking)
* Temperature sensor = "sensor" explained in chapter 6.9.
Page of 32