NN-GM231WZPE - Panasonic Home Appliance Service Manual (repair manual). Page 23

Read Panasonic NN-GM231WZPE Service Manual online

5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitors
and secondary
switches.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor
and secondary
switches.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
(TROUBLE 1) Oven lamp does not turn on when the timer is set with door closed.
(TROUBLE 2) Oven does not start even though the timer is set.
NOTE : All these switches must be replaced at the same time.
1. Oven does not
operate.
No continuity.
No continuity.
Adjust or replace.
Malfunction of the
primary switch.
Malfunction of the
secondary switch.
Adjust or replace.
Check theĀ 
continuity of the
primary switch.
with door
closed.
Check the
continuity of the
secondary
switch with
secondary
switch pushed.
Page of 35
Display