4.2.1. To replace magnetron
 1. Remove air guide D.
 2. Remove 2 screws holding air guide F.
 3. Remove 1 screw holding thermistor on magnetron.
 4. Remove 3 screws holding magnetron.
NOTE:
After
replacement
of
the
magnetron,
tighten
mounting screws properly, making sure there is no
gap between the waveguide and the magnetron to
prevent microwave leakage.
CAUTION
When replacing the magnetron, be sure the antenna gasket is in
place.
4.2.2. To replace H.V Inverter
 1. Release 4 catch hooks, then remove inverter cover.
 2. Remove 2 screws holding H.V. Inverter.