Read Panasonic NC-PF30PV Service Manual online
60 80 90 98
- 5 -
NC-PF30PV
1.1.3. Pour out test (Electric pump type)
How to operate
How to operate
1. Pour hot water into Container.
2. Supply with electric power.
3. Press UNLOCK pad.
4. Press POUR OUT pad.
2. Supply with electric power.
3. Press UNLOCK pad.
4. Press POUR OUT pad.
Operating detail
If press UNLOCK pad then POUR OUT pad, water will
be poured out from Dispensing Spout.
1.1.4. LCD monitor display test
How to operate
How to operate
1. Pour water into the container.
2. Press TIMER pad, LONG BOIL/REBOIL pad,
SELECT pad all together, and then supply electric
power.
Press at the same time.
1.1.5. Pour out test (Air pump type)
How to operate
How to operate
1. Pour hot water into Container.
2. Change Lock Knob botton to unlock.
3. Push on Supporting Plate.
2. Change Lock Knob botton to unlock.
3. Push on Supporting Plate.
Operating detail
If push Supporting Plate, water will poured out from
Dispening Spout.
LCD monitor will display as picture below.
1.2. Dismantle Procedure for
Failure Diagnotics
Tapping screw
(M4 x 12)
Truss head screw
Bottom plate
Sleeve
Screw B
Waterproof
cover B
Body
Microcomputer in thermo pot, may break down
by static electricity from clothes, human body,
workbenches,etc. when toutch or wonder to toutch
should to ground human body with several MΩ.
SOMETHING REQUEST
Do not do maintennance and re-use if copper
pattern on PCB is broken.
1. Remove 2 Tapping screws and 1 Truss head
screw from Bottom plate.
2. Remove 1 screw and Sleeve from Body.
3. Remove blue, black Lead wire and Earth wire
from Peg frame.
4. Remove Body off.
5. Remove Water proof cover B.
Click on the first or last page to see other NC-PF30PV service manuals if exist.