UF-490, UF-4000, UF-4100 - Panasonic Fax Service Manual (repair manual). Page 115

Read Panasonic UF-490 / UF-4000 / UF-4100 Service Manual online

115
412
G3 RX
B, D
No response within 12 seconds in 
NSS/DCS/MPS wait state. (After 
transmitting FTT)
Transmitter is defective.
SC PCB is defective.
414
RCV
(Polling)
B
No response received after 
transmitting 3rd NSC.
Password does not match between 
transmitter and receiver.
Transmitter is defective. (No original, 
document jam, etc.)
415
XMT
(Polling)
B
Remote side attempted to receive 
message from your machine in 
polling communication.
Inform the remote side that your 
machine does not have the polling 
transmission feature.
416
RCV
D
Receiver did not detect post 
command, such as EOP, MPS, 
EOM, etc.
Transmitter is defective.
Line quality is poor. (RTC signal is 
distorted due to line noise)
SC PCB is defective.
417
RCV
C
Receiver returned RTN in 
response to post message.
Line quality is poor. (There are 
excessive errors in received data)
SC PCB is defective.
418
RCV
C
Receiver transmitted PIN in 
response to PRI-Q from 
transmitter. (Transmitting operator 
requests voice contact)
Line quality is poor. (There are 
excessive errors in received data)
SC PCB is defective.
420
RCV
B
T1 timer (35 sec.) elapsed without 
detecting 300 bps signal.
There is wrong incoming call.(non-
facsimile communication)
Transmitter is defective.
SC PCB is defective.
421
RCV
B
Busy Tone is detected after 
sending NSF Signal.
Remote station disconnected the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC 
(or DTC) was invalid.
There is an incompatibility.
427
G3 
RCV
B
DCN received to NSF/CSI/DIS 
transmitted.
The interface is incompatible.
433
XMT 
RCV
B, D
T.30 Protocol abnormal.
Defective remote station.
434 XMT or RCV
B
CD (response from Modem) did 
not turn OFF within 180 sec. after 
receiver detected FLAG signal.
Remote unit is defective.
SC PCB is defective.
436
G3 RX
C
DCN received after transmitting 
FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456
RCV
B
Received relay transfer request or 
confidential document to distribute 
to an end receiving station or all 
confidential mailboxes are used.
459
RCV
C
Failed training in Phase C.
Line quality is poor. (Training signal is 
distorted due to line noise)
SC PCB is defective.
490
RCV
C
Sum of error lines exceeded the 
limit (Function Parameter No. 70) 
of 64 lines.
Line quality is poor.
SC PCB is defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause